5.2 Emergency power supply

If the battery is discharged with the door locked, the lock can be powered up using the emer-
gency power supply connection. To do this, a 9-volt block battery must be connected to the
supply clip beneath the cover of the control unit.
Cover
Raise here
Tool
Press tool into the right hand or upper (in case of vertical installation) hole on the bottom
edge of the control unit until the catch is released. Keep the tool pressed down whilst the
cover raising carefully.
Repeat this process on the left hand or down (in case of vertical installation) hole. Lift off the
cover carefully.
Pull out the battery clip for the emergency supply by about 1 cm and clip in a 9-volt block
battery. Open the lock with a valid code, remove the block battery from the clip and replace
the discharged battery in the lock case.
Replace the cover and press down until all four catches are engaged. Check that the lock
functions correctly whilst the safe is still open.