Prior to installation
Flush main water supply inlet line prior to making connections.
Only teflon tape to be used where necessary, under no circumstances is
plumbing paste to be used.
When fitting this unit in a cupboard of small proportions, please note that the
unit does omit heat. We recommend a vent is fitted.
Do not connect to the boiler unit to the hot water line or the fire hydrant supply,
to do so will void the warranty.
Requires 2 x 3 pin 10 amp power sockets.
Product Information
The boil unit is fitted with a computerised element and boil dry protection. The
computer is set at 95 Degrees C, altitude will alter the boiling point.
The 350 kPa Pressure Limiting Valve supplied must be fitted.
We recommend changing the water filter cartridge every 12 months.
We recommend the cleaning and servicing of the units every 24 months, or
every 12 months in hard water areas.
If the supplied power cord is damaged it must be replaced by an electrician
This configuration requires Minimum Inlet Pressure 260 kPa.

Installation Instructions

1. Do not plug in the units or turn on the power until the installation
process is complete.
2. Position the Fusion Boil & Chill tap at the rear of the sink in a workable
location relative to the mixer. Cut a 38mm hole to facilitate mounting
of the tap. Secure the tap by tightening the bracket securing nuts supplied.
3. Position the Boil unit underneath the sink in a position that does not
require extensions to be made in the installation hoses that are
permanently affixed to the bottom of the Fusion Boil & Chill Dispenser
Tap. The Boil unit hoses may be cut to fit, but never extended.
4. Position the Chiller unit underneath the sink so that the chiller air-intake
is as close as possible to the front of the cupboard. The cupboard floor
which extends past the toe-board must have a slot cut into it to provide the
necessary ventilation (pref at least 20mm wide by 3/4 the width of the
cupboard door). The white inlet and outlet hoses from the Boil & Chill
Dispenser Tap can be extended in length if necessary.
5. Secure the 10" Filter with the bracket and screws provided to the
cupboard wall in a handy position relative to the mains inlet line as shown,
taking careful note of which ports are Outlet and Inlet
6. The filter cartridge comes with quick fit John Guest connections, push
the correct inlet/outlet tubes ends into the fittings and pull back carefully
to secure.