Prior to installation
• This unit is intended to be installed underneath a conventional
kitchen sink. However as a refrigeration unit it relies upon air
exchange to function properly, ensure adequate ventilation is
provided.
• When fitting this unit in a cupboard leave 25mm in the front and
back of the unit and 50mm either side of the unit.
• Only Teflon tape to be used where necessary. Under no
circumstances is plumbing paste to be used.
Product Information
• The 350 kPa Pressure Limiting Valve supplied must be fitted.
• Do not tip chiller unit on its side or end, if this has happened
reposition and wait 30 minutes for the oils to return.
• We recommend changing the filter cartridge every 12 months.
• The condenser should be periodically cleaned with a brush air
hose or vacuum cleaner. Disconnect the power supply during
cleaning.
• If the supplied power cord is damaged, it must be replaced by an
electrician.
• Temperature control is adjustable, with a cooling capacity of 2-12
degrees Celsius.

Installation Instructions

1. Do not plug in the unit or turn on the power until the installation
process is complete.
2. Position the unit underneath the sink so that the chiller air-intake
is as close as possible to the front of the cupboard. The cupboard
floor which extends past the toe-board must have a slot cut into it
to provide the necessary ventilation (preferably at least 20mm
wide by 3/4 the width of the cupboard door).
3. Ensure the connecting lines are thoroughly flushed to remove all
foreign matter before connection to the chiller.
4. Position the tap in the desired location. Drill an 11mm hole to fit.
5. Secure the 10" Water Filter, with the bracket and screws
provided, to the cupboard wall in a handy position relative to the