3.17Parameter save

Saves the following parameters so that they become
the default parameters when the tape deck is next
powered up:
• Single Play
• Skip Play
• Repeat Mode
When this menu item is first displayed, the right side
of the display shows:
settings, turn the DATA dial [20], so that the display
, and press ENTER [27].
shows

3.18Initializing settings

Resets all menu values to their default settings except
for the head time, (see 3.1, "Drum time (head
time)"), which cannot be reset.
To reset the values to default, turn the DATA dial
[20] so that the display shows
ENTER [27].
. To save the current
and press
3 - Menu functions
If the screen shows
dial again so that the display shows
3.19Viewing points at which block
errors have occurred
ABS
H
M
S
This display is shown if the MENU key is pressed
once more following the reset screen above.
This displays up to five points in ABS time format
where more than one block error has occurred within
a frame. Turn the DATA dial to view the five points at
which these errors have occurred. Turning the dial
clockwise after error #5 will show the total number
of such errors (up to a total of 99 errors).
While a block error time is shown on the display,
pressing the LOC 2 key will write the error location
to the second location memory and start locating the
tape to that point.
While any of the locations or the total number of the
tape errors menu is shown on the display, the infor-
mation can be cleared by pressing the MARGIN
RESET key. Ejecting the tape will also clear this
data.