Checking The Static Pressure And Supply Pressure - Viessmann VITODENS 111-W Installation And Service Instructions Manual

4.7 to 35.0 kw gas condensing storage combi boiler natural gas and lpg version
Table of Contents

Advertisement

Changing the gas type
Selected gas type
Delivered condition
Changed to
Changed to

Checking the static pressure and supply pressure

Danger
CO formation as a result of incorrect burner
adjustment can have serious health implications.
Check the CO content before and after carrying
out work on gas appliances.
Operation with LPG
Purge the LPG tank twice on commissioning or
replacement. Vent the tank and gas connection line
thoroughly after purging.
A
Fig. 18
1. Close the gas shut-off valve.
2. Undo screw
A
inside test connector "IN" on the
gas train, but do not remove it. Connect the pres-
sure gauge.
3. Open the gas shut-off valve.
4. Check the static pressure.
Set value: max. 57.5 mbar (5.75 kPa)
Commissioning, inspection, maintenance
(cont.)
Gas
Date
CO
content in
2
type
G 20
7.5 - 10.5
5. Start the boiler.
Note
During commissioning, the appliance can enter a
fault state because of airlocks in the gas line. After
approx. 5 s, tap and hold "R" for approx. 2 s to
reset the burner.
Ensure that enough heat is being drawn during the
testing and setting processes.
6. Check the supply (flow) pressure.
Set value:
Natural gas: 20 mbar (2.0 kPa)
LPG: 50 mbar (5.0 kPa)
Note
Use a suitable tester with a resolution of at least
0.1 mbar (10 Pa) to check the supply pressure.
7. Implement measures as indicated in the table
below.
8. Shut down the boiler and close the gas shut-off
valve. Remove the pressure gauge and seal test
connector
9. Open the gas shut-off valve and start the appli-
ance.
Note
The maximum pressure drop between the gas shut-off
valve and test connector
0.5 mbar (50 Pa).
O
content in % CO content in
2
%
with screw.
A
Danger
Gas escaping from the test connector leads
to a risk of explosion.
Check gas tightness at test connector
at the gas train is
A
ppm
< 1000
< 1000
< 1000
A
.
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents