Rack Positions; Replacing Oven Lamp - FG Europe MFA1-6 Series User Manual

60 cm
Table of Contents

Advertisement

GB

Rack Positions

Rack 4
Rack 3
Rack 2
Rack 1
Installing and removing wire racks
To remove wire racks, press the clips shown with arrows in the figure,
first remove the lower, and than the upper side from installation location.
To install wire racks; reverse the procedure for removing wire rack.

Replacing Oven Lamp

WARNING: To avoid electric shock, ensure that the appliance circuit is
open before changing the lamp. (having circuit open means power is off)
First disconnect the power of appliance and ensure that appliance is cold.
Remove the glass protection by turning as indicated in the figure on the
left side. If you have difficulty in turning, then using plastic gloves will
help you in turning.
Then remove the lamp by turning, install the new lamp with same
specifications.
Reinstall glass protection, plug the power cable of appliance into electrical
socket and complete replacement. Now you can use your oven.
Type G9 Lamp
It is important to place the wire grill into
the oven properly. Do not allow wire rack to
touch rear wall of the oven. Rack positions
are shown in the next figure. You may place
a deep tray or a standard tray in the lower
and upper wire racks.
220-240 V, AC
15-25 W
Figure 13
Type E14 Lamp
32
220-240 V, AC
15 W
Figure 14