18. FAULT CODES

There are error codes that may be displayed. These will be displayed in the
following way:
Power on
Error Code
lamp
Polarity Reverse
/ Output Short
Non Battery
Link
Faulty
Battery
Over Voltage
Over
Temperature
Stage
Fault
Cause
lamp
lamp
Short circuit or
reverse
connection of the
clips
Non battery link
Bulk charging
has timed out
and stopped after
(Step 3
24 hours.
lamp)
The 12V battery
voltage is above
17.5V.
The 24V battery
voltage is above
35V.
Internal
temperature
is above
65 C +/-5 C
17
Check clips are not
touching each other
OR Check the clips are
correctly connected to
the battery.
Please choose the
right battery type for
connection.
Battery is faulty and
may need to be
replaced.
Disconnect the
charger and check
the battery voltage.
This charger is
suitable for 12V or
24V Batteries only.
Turn off charger and
allow to cool.
O
O
Remedy

Hide quick links: