8-STAGE AUTOMATIC
BATTERY CHARGER & MAINTAINER
MCU CONTROLLED & HIGH FREQUENCY SWITCHMODE
P/No. BC8S1205A、BC8S1207A、BC8S1210A、BC8S1212A
BC8S1215A、BC8S1220A、BC8S2405A、BC8S2410A
Instruction Manual
Please read user manual carefully before use.

Advertisement

Table of Contents
loading

Summary of Contents for VMAXTANKS BC8S1205A

  • Page 1 8-STAGE AUTOMATIC BATTERY CHARGER & MAINTAINER MCU CONTROLLED & HIGH FREQUENCY SWITCHMODE P/No. BC8S1205A、BC8S1207A、BC8S1210A、BC8S1212A BC8S1215A、BC8S1220A、BC8S2405A、BC8S2410A Instruction Manual Please read user manual carefully before use.
  • Page 2 1. WARNING ◆ Explosive gases may escape from the battery during charging. Prevent flames and sparks. Provide adequate ventilation. ◆ Before charging, read the instructions. ◆ For indoor use. Do not expose to rain. ◆ For charging 12v agm gel and sla batteries. ◆...
  • Page 3 The 8-stages are:Desulphation ; Soft Start; Bulk; Absorption; Analyse; Recondition; Float and Puls STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7 STEP 8 REMOVES HARMFUL SOFT START INCREASES MAIN CHARGING TOP CHARGE TESTS RECONDITIONS FULLY CHARGED MAINTENANCE SULPHATE DEPOSIT...
  • Page 4 Desulphation The Desulphation stage may break down sulphation that occurs in batteries that have been left flat for extended periods of time, returning them back to full charge. Sulphation occurs when lead-sulphate hardens and clogs up the battery cells. Soft Start A preliminary charge processes that gently introduces power to the battery.
  • Page 5 Float The Float stage maintains the battery at 100% charge without overcharging or damaging the battery. This means the charger can be left connected to the battery indefinitely. Pulse Maintaining the battery at 95-100% capacity. The charger monitors the battery voltage and gives a pulse when necessary to keep the battery fully charged.
  • Page 6: Product Overview

    5. PRODUCT OVERVIEW The 8-stage automatic charging consists of the following components: 1.Mode button 2.Stage lamp status display indicates power, charging and fully charged. 3.Power lamp 4.Fault lamp 5.Output voltage meter 6.Battery mode lamp 7.DC leads. 8.Power Cord 9.Thermostatically controlled cooling fan. 10.Ground terminal 11.Mounting flange.
  • Page 7: Charge Status Indicator

    6. CHARGE STATUS INDICATOR The CHARGING and STAGE LAMP will illuminate and flash in various patterns to indicate the different stages of charging. See below for flash / steady patterns. Power on Stage Fault lamp lamp lamp display Power Off Power On 1.
  • Page 8: Power On Lamp

    STAGE LAMP: illuminates and flashes when 8-stage charging process. STAGE LAMP: illuminates solid when fully charged. POWER ON LAMP If the power lamp is lit with a: 1. STEADY LIGHT The mains cable is connected to the wall socket. 2. FLASHING LIGHT The charger has entered the energy save mode.
  • Page 9: Specifications

    7. SPECIFICATIONS P/No. BC8S1205A BC8S1207A BC8S1210A Charger Type 8-Stage automatic 220-240V~, 50/60Hz 110V~, 60Hz Input Voltage Input Power 154W 215W 307W Output Voltage 12V DC 12V DC 12V DC Output Current Minimum Start Voltage 2V Back Drain Current Fuse Rating 250VAC, T3.15A...
  • Page 10 8. SPECIFICATIONS P/No. BC8S1212A BC8S1215A BC8S1220A Charger Type 8-Stage automatic Input Voltage 220-240V~, 50/60Hz 110V~, 60Hz Input Power 332W 415W 554W Output Voltage 12V DC 12V DC 12V DC Output Current Minimum Start Voltage 2V Back Drain Current Fuse Rating 250VAC, T3.15A 250VAC, T3.15A 250VAC, T5A...
  • Page 11 9. SPECIFICATIONS P/No. BC8S2405A BC8S2410A Charger Type 8-Stage automatic Input Voltage 220-240V~, 50/60Hz 110V~, 60Hz Input Power 296W 547W Output Voltage 24V DC 24V DC Output Current Minimum Start Voltage Back Drain Current Fuse Rating 250VAC, T3.15A 250VAC, T5A CHARGE CONTROL Desulphation Pulse charge up to 22V Soft Start...
  • Page 12: Charging Instructions

    10. CHARGING INSTRUCTIONS 1. Settings are made by pressing the MODE-button. After about two seconds the charger activates the selected program. The selected program will be restarted next time the charger is connected. 2. To turn off the charger by pressing and holding the MODE-button for 3 seconds. 3.
  • Page 13 11. Negatively earthed (most vehicles) Connect the RED lead (battery clip) from the charger to the Positive (+) battery terminal. Connect the BLACK lead (battery clip) from the charger to the vehicle's chassis away from the fuel line or moving parts. BLACK F A N Connection in vehicle...
  • Page 14 13. CHASSIS EARTHING The chassis earthing lug should be connected to an earting point which will be depending on where the battery charger is installed. In a vehicle, connect the chassis ground lug to the chassis of the vehicle. In a boat, connect to the boat's grounding systems.
  • Page 15: Mounting Instructions

    14. MOUNTING INSTRUCTIONS 8-stage chargers are designed for indoor, out of weather use only. Ensure that both charger and battery are in a well-ventilated space during charging. The battery charger end plates include a mounting flange for easy mounting. If permanently fixed the charger should be mounted to a suitable horizontal or vertical panel, with at least 10cm clearance from the end plates to provide adequate ventilation for the cooling fan.
  • Page 16 15. PERMANENT WIRING TO BATTERY It is possible to hard wire the DC charging leads to the battery for permanent installations. You will need 2 x ring terminals, an inline fuse holder and a fuse with a rating equal to or more than twice of the chargers output. (See below) 4A = 8 Amp fuse 5A = 10 Amp fuse 7A = 15 Amp fuse 10A = 20 Amp fuse...
  • Page 17 16. ADJUSTABLE CHARGE RATES: 12 VOLT BATTERY CHARGE RATE BATTERY SIZE (12V) Battery size (Ah) Charger time (hours) 5Amp 20-75 4-15 7Amp 28-105 4-15 10Amp 40-150 4-15 12Amp 48-180 4-15 15Amp 60-225 4-15 20Amp 80-400 4-15 17. ADJUSTABLE CHARGE RATES: 24 VOLT BATTERY CHARGE RATE BATTERY SIZE (24V) Battery size (Ah) Charger time (hours)
  • Page 18: Fault Codes

    18. FAULT CODES There are error codes that may be displayed. These will be displayed in the following way: Power on Stage Fault Remedy Error Code Cause lamp lamp lamp Check clips are not Short circuit or touching each other Polarity Reverse reverse OR Check the clips are...
  • Page 19 FREQUENTLY ASKED QUESTIONS Q. How do I know if the battery is charged? A. The charger's FULLY STAGE LAMP will illuminate (solid). Alternatively use a Battery. Hydrometer A reading of 1.250 or more in each cell indicates a fully charged battery. Q.
  • Page 20 CAUTION ALWAYS PLACE THE BATTERY CHARGER IN AN ENVIRONMENT WHICH IS: A. WELL VENTILATED. B. NOT EXPOSED TO DIRECT SUNLIGHT OR HEAT SOURCE. C. OUT OF REACH FROM CHILDREN. D. AWAY FROM WATER / MOISTURE, OIL OR GREASE. E. AWAY FROM ANY FLAMMABLE SUBSTANCE. F.