Oliveri Paris Wall Spout Series Installation Instructions

Advertisement

Quick Links

THIS BASIN/BATH SPOUT MUST BE INSTALLED BY A LICENSED PLUMBER IN
ACCORDANCE WITH LOCAL REGULATIONS
This Oliveri tap is manufactured to standard AS/NZS 3718.
MAX OPERATING PRESSURE: ..............................................................5 bar (500kPa)
RECOMMENDED OPERATION PRESSURE:
..........................................1.5-5 bar (150-500kPa)
MAX HOT WATER TEMPERATURE: .....................................................65°C
RECOMMENDED HOT WATER TEMPERATURE:
..................................50°C
Where water pressure exceeds 500kPa, a pressure reducing device is required to be installed. Note that
water pressure overnight can reach 150% of the daytime pressure.
Note: Warranty claims will not be honoured where the spout has malfunctioned due to
the presence in the water supply of ;
Note: Installation of aerators containing flow regulators.
Upon re-installation, the aerator should be tightened with an aerator key to prevent removal by hand.
Note: - Copper tube pieces, sand, dirt or stones
- Thread tape
- Other objects not normally present in potable water supplies.
Before attempting any work involving mains water supply lines, ensure the water supply is shut off.
This basin/bath spout must be installed in accordance with these instructions.
Issue Date 30/11/2018 Revision Number: V1.0
PA102200CR/PA102206MB/PA102200BN
Paris Wall Spout
CARE & MAINTENANCE
Clean with a soft cloth and warm soapy water as necessary - rinse and dry after cleaning. Under No
Circumstances should abrasive or acid based cleaning products be used.
WARRANTY
This basin/bath spout is warranted to be free from manufacturing defects for a period of 10 Years: 10 years for body,
5 years for seals, tails, fittings and aerators, 1 year for finish and labour, when used in a domestic situation.
This warranty does not cover against normal wear and will be voided if the product is misused or
not installed in accordance with these instructions.
filters, to this spout will void warranty.
In the event this product is rendered obsolete and a replacement product is required, Oliveri Solutions Pty Ltd
reserves the right to supply a product of equal substitution at their discretion.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are
entitled to a replacement or refund for a major failure and for compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to
be of acceptable quality and the failure does not amount to a major failure.
SERVICE
If the problem represents a danger, or damage to property may occur, immediately shut off the water
supply. If the spout requires servicing, please contact your plumber (preferably the one who installed
it). Most problems occur due to contaminated supply lines or water pressure exceeding 500KPa.
Unscrew and clean the spout aerator periodically - especially if you notice a drop in water pressure.
If the Plumber / Installer is satisfied that the problem is not due to poor installation, contact T2 Services Pty Ltd
for assistance on:
Ph: (07) 55960738
Fax: (07) 55273353
Email: oliveri@t2services.com.au
https: //oliveri.com.au/service-and-warranty
If a warranty service agent finds that the spout is not at fault, T2 Services Pty Ltd reserves the right to
pass on any callout fee to the householder.
PA102200CR/PA102206MB/PA102200BN installation instructions.pdf
Note: Fitting spout-attached devices, including water

Advertisement

loading

Summary of Contents for Oliveri Paris Wall Spout Series

  • Page 1 Upon re-installation, the aerator should be tightened with an aerator key to prevent removal by hand. filters, to this spout will void warranty. In the event this product is rendered obsolete and a replacement product is required, Oliveri Solutions Pty Ltd reserves the right to supply a product of equal substitution at their discretion.
  • Page 2 Installation Instructions General Note: This product is to be installed by a licensed plumber, installation must comply with AS/NZS 3500 and local plumbing codes. Pressures & Temperatures Maximum Hydrostatic Pressure – 500 kpa. (As per AS/NZS3500) Note: AS/NZS 3500.1-2003 (Clause 3.3.4) states that “Provision shall be made to ensure that the maximum static pressure at any outlet, other than a fire service outlet, within a building does not Max 18mm 1/2BSP thread exceed 500 kPa.