upper jam nut
lower jam nut
forward cable ,
0.
reverse cable
bracket
ADJUSTMENTS
v
r
DEPTH REGULATOR LEVER
Tilling depth is controlled by the height of the depth
regulator lever.
To adjust tilling depth.
Remove detent pin.
Raise the depth regulator lever to position tines at
chosen tilling depth.
Align hole in depth regulator lever with hole in depth
regulator bracket and replace detent pin.
Depth Regulator Lever Down = Shallower tilling. Place
the detent pin in the top hole of the depth regulator lever
for shallowest tilling.
Depth Regulator Lever Up = Deeper tilling. Place the
detent pin in the bottom hole of the depth regulator lever
for deepest tilling.
A
CAUTION
Always set the depth regulator lever in the transport
position before starting engine, that is, place the detent
pin in the highest hole of the depth regulator lever.
A
CAUTION
Do not adjust tilling depth unless drive control levers
are released to neutral position.
BELT TENSION ADJUSTMENT
Proper belt tension is critical to good performance. After
1/2 hour of operation, all cables may have to be adjusted
due to initial stretch. Thereafter, check tension after every
2 hours of operation.
To increase belt tension:
1. Loosen upper jam nut. Turn nut up cable in 1/8"
increments.
Tighten lower jam nut.
Check adjustment.
This procedure can be repeated until conduit adjustment
bolts have no more adjustment left. If no more
adjustment can be made, belt may have to be replaced.
12