Electrolux EHI845BB Installation & User Manual page 9

Hide thumbs Also See for EHI845BB:
Table of Contents

Advertisement

16
electrolux.com
ware may be knocked off the rings when doors and windows
are opened.
ffi
Caution! Warning! Risk of injury
from electrical current.
• The electrical mains terminal is live. Make electrical
mains terminal free of volt­age.
Follow connection schematic.
• Observe electrical safety rules.
• Ensure anti-shock protection by installing correctly.
• The appliance must be connected to the electrical
supply by a qualified electrician.
• Loose and inappropriate plug and socket
connections can make the terminal over­heat.
Have the clamping connections correctly installed
by a qualified electrician.
Use strain relief clamp on cable.
• A ventilation gap of 5 mm underneath the cooktop
must be left.
ffi Caution! The surface temperature
exceeds 95°C. To avoid a hazard,
underbench access must be restric­ted
Electrical Connection
Before connecting, check that the nominal voltage of
the appliance, that is the voltage stated on the rating
plate, corresponds to the available supply voltage.
Also check the power rating of the appliance and
ensure that the wire is suitably sized in accordance
with local wiring rules to suit the appliance power
rating. The rating plate is located on the lower casing
of the hob. The heating element volt­age is AC230V-.
The appliance also works perfectly on networks with
AC220V- or AC240V-. Means for disconnection must
be incorporated in the fixed wiring in accord­ance
with local wiring rules.The hob is to be connected to
the mains using a device that allows the appliance to
be disconnected from the mains at all poles with a
contact
opening width of at least 3 mm, eg. auto­matic line protecting cut-
out, earth leakage trips or fuse. If this appliance's mains cable is
damaged, it must be replaced by a special cable
(type H0SBB-F T max 90℃; or higher).
The latter is available from the Customer Care Department.
The connection must be carried out as shown in the diagram.
The earth lead is connected to termi-nal � .
The earth lead must be longer than leads carrying electric current.
The cable connections must be made in accord-
ance with regulations and the terminal screws tightened securely.
Finally, the connecting cable is to be secured with the mains cable
cleat and the covering closed by pressing firmly (lock into place).
Bef o re switching on for the first time, any protective foil or stickers
must be removed from the glass ceramic surface.
ffi Warning! Once connected to the
mains supply check that all cooking
zones are ready for use by briefly switching
each on in turn at the maximum setting.
• A duplicate rating label is supplied with this unit. For easy
identification of this unit after installation, stick it to a readily
available surface adjacent to the cooktop.
Sticking on the seal
• Clean the worktop around the cutout area.
• Stick the single-sided adhesive sealing tape provided on the
underside of the hob around the outside edge ensuring that it is
not stretched. The two ends of the tape should join in the middle
of one side. After trimming the tape (allow it to overlap by 2-3
mm), press the two ends together.
Assembly
min.
500mm
min.
50mm
min.
5mm
When fitting a vent hood above the hob, refer to
the manufacturer own installations relating to that
product. However as a general rule, a minimum
clear vertical distance of 500mm.
780
520
490
0
75
=
=
Waring! Surface temperatures of base exceed 95℃.
under bench access must be restricted by use of non-combustible barrier on installation
17