General Information; Optional Parts; Remote Control; Multiple Remote Controller - Fujitsu ARXG12-54KHTAP Operating Manual

Duct type
Table of Contents

Advertisement

Filter indicator reset (Special setting)
This function can be used if set correctly during installation. Please
consult authorized service personnel in order to use this function.
1. Clean the air fi lter when the fi lter indicator appears.
2. After cleaning, reset the fi lter indicator.
* For detailed instructions on how to operate, please refer to the
operating manual of the remote controller.

8. GENERAL INFORMATION

■ Inverter
On start-up, the air conditioner will operate at maximum capacity to
bring the room quickly down to desired temperature.
Once the temperature in the room begins to achieve the set
temperature, the air conditioner will reduce its capacity and energy
usage to the minimum capacity and input ratings.
■ Heating performance
This air conditioner operates on the heat-pump principle, absorbing
heat from air outdoors and transferring that heat to the indoor unit. As a
result, the operating performance is reduced as outdoor air temperature
drops.
If you feel that the heating performance is insuffi cient, we recommend
you to use this air conditioner in conjunction with other kinds of heating
appliance.
Please consult with your installation technician to ensure the unit is
correctly sized for the room space required.
Heat-pump air conditioners heat your entire room by recirculating air
throughout the room, with the result that some time may be required
after fi rst starting the air conditioner until the room is heated.
■ Automatic defrosting operation
When outdoor temperature is very low with high humidity, frost may
form on the outdoor unit during the Heating operation, and it could
reduce the operating performance of the product.
For frost protection, a microcomputer-controlled automatic defrost
function is equipped in this air conditioner.
If frost forms, the air conditioner will temporarily stop, and defrost circuit
will operate briefl y (maximum of 15 minutes.)
If frost forms on the outdoor unit after the Heating operation, the outdoor
unit will stop automatically after it operates for a few minutes. Then the
automatic defrosting operation starts.
If you set to the Heating operation during the Automatic defrosting
operation, the Automatic defrosting operation will continue. The Heating
operation will begin after completion of defrosting. As a result, It may
take some time before warm air is emitted.
■ Hot start
The indoor unit prevents cold drafts when the Heating operation be-
gins.
The indoor unit fan will not operate or it will operate at a very low speed
until the heat exchanger reaches the set temperature.
■ Auto-restart function
In Event of Power Interruption
Should the power supply to the air conditioner be interrupted by a power
failure, the air conditioner will restart automatically in the previously
selected mode once the power is restored.
■ Malfunctions caused by other electrical
devices
Use of other electrical appliances such as an electric shaver or nearby
use of a wireless radio transmitter may cause the malfunction of the air
conditioner.
If you encounter such a malfunction, disconnect the power supply once.
Then reconnect it, and resume operation by using the remote controller.
En-5
■ Indoor unit temperature and humidity range
Permissible ranges of temperature and humidity are as follows:
Indoor temperature
Cooling/Dry
Heating
Indoor humidity
*1) If the air conditioner is used continuously for many hours, water may
condense on the surface and drip.
• If the unit is operated under the conditions except the permissible
temperature range, the air conditioner operation may stop because
of the automatic protection circuit working.
• Depending on the operating conditions, the heat exchanger may
freeze, causing water leakage or other malfunction. (in the Cooling
or Dry mode).
■ When indoor and outdoor temperatures are
high
When both indoor and outdoor temperatures are high during use of the
Heating mode, the outdoor unit's fan may stop at times.
■ Low ambient cooling
When the outdoor temperature drops, the outdoor unit's fans may switch
to low speed, or one of the fans may stop intermittently.
■ Other informations
• Do not use the air conditioner for any purpose other than room
cooling/dry, room heating or fan.
• For the permissible ranges of temperature and humidity for the
outdoor unit, refer to the outdoor unit installation manual.
• During the Heating mode, the top of the indoor unit may become
warm, but this is due to the fact that coolant is circulated through the
indoor unit even when it is stopped; it is not a malfunction.

9. OPTIONAL PARTS

9.1. Remote control

The remote controller is optional. You can select from the
following types of remote control.
- Wireless remote controller
- Wired remote controller
- Wireless LAN control
To check the available model of remote controller, please consult
authorized service personnel.
NOTES: depending on the remote control, some function may be
restricted. Please refer to the operating manual of the remote
controller or WLAN adapter for details.
You can use both wireless and wired remote controller together.
However, some functions of the wireless remote controller may be
restricted.

9.2. Multiple remote controller

You can connect two wired remote controllers to one air conditioner.
Either remote controller can control the air conditioner.
However, the timer functions cannot be used by the secondary unit.

9.3. Group control

One wired remote controller can control up to 16 air conditioners. All of
the air conditioners will be operated with the same settings.
You cannot use group control and wireless LAN control together.
[°C]
18 to 32
[°C]
16 to 30
1)
[%]
80 or less *

Advertisement

Table of Contents
loading

Table of Contents