An ISO 15223 symbol Indicating upper and lower humidity limits An ISO 15223 symbol Indicating upper and lower atmospheric pressure limits “Conformité Européenne” Tracker Freedom products meet the provisions of the (“European Conformity”) Council Directive 93/42/EEC 0086 An EN 980 symbol...
Warnings and Notifications This manual covers installation and basic operation of the Tracker Freedom wireless interface . For software and instrument operation see the Tracker Version 5 User’s Guide . For your convenience copies of all user guides are contained on your Tracker Software CD .
ISO 13485:2003 with Canadian Medical Devices Conformity Assessment System (CMDCAS) Intended Use and Indications for Use The intended use of the Tracker Freedom family of products is to assist clinicians in obtaining patient information about physical strength and flexibility . The devices are intended to be used as non- invasive, non-surgical and transient devices .
Instrument batteries must be fully charged before attempting to use them with Notice: your Tracker Freedom System . Each instrument must charge for at least six (6) continuous hours before its first use . Do not use more than one daisy chain with each power supply as it will affect the charge strength .
Note: Newer computers may first display an “AutoPlay” menu for security purposes . Choose the option to “Run autorun .exe” to continue) . 2 . At the Welcome screen, select “Install Tracker Freedom Drivers . ” 3 . The Tracker Freedom Driver Installation window will appear with instructions .
Page 10
30 days, we recommend recharging the battery before use . Instrument Activation Before a Tracker Freedom instrument is used to collect data, it must be turned on . 1 . To use a Tracker Freedom instrument, open a testing screen that uses the instrument, such as Inclinometry - Cervical Flexion/Extension, and the software signals the Receiver to look for the instrument .
. Foot Switch Operation The Tracker Freedom System may include a two-button foot switch - one button for "ENTER" and the other for "NEXT ." The ENTER button functions primarily for entering neutral (or zero) and data points with the Inclinometers, Goniometer and Algometry .
VELCRO® strap and then remove the strap from the subject . 3 . Push the “On” button on the Inclinometer to enable communication with the Tracker Freedom Receiver . If necessary, repeat this procedure for the other Inclinometer .
Curved Pad, or Algometry Tip must be used with the Muscle Tester . 2 . Push the “On” button to enable communication with the Tracker Freedom Receiver For instructions on operating the Tracker software, please refer to the Tracker software...
. 2 . Push the “On” button to enable communication with the Tracker Freedom Receiver For instructions on operating the Tracker software, please refer to the Tracker software...
. Note: One of the Algometry Tips must be used with the Algometer . 2 . Push the “On” button to enable communication with the Tracker Freedom Receiver For instructions on operating the Tracker software, please refer to the Tracker software...
Allows patients control the end of the test using the Enter button . 1 . Turn on the Tracker Freedom Algometer . 2 . Push the “On” button to enable communication . For instructions on operating the Tracker software, please refer to the Tracker software manual For troubleshooting information, please see page 23 .
Do not bend, or twist the extension to disengage as the extension may break . 3 . Push the “On” button to enable communication with the Tracker Freedom Receiver For instructions on operating the Tracker software, please refer to the Tracker software...
Static Force Gauge . 2 . Push the “On” button to enable communication with the Tracker Freedom Receiver . For instructions on operating the Tracker software, please refer to the Tracker software manual .
(9RF109) Used to convey functional abilities concerning pinch strength . 1 . Push the “On” button to enable communication with the Tracker Freedom Receiver For instructions on operating the Tracker software, please refer to the Tracker software manual For instructions on performing specific tests, please refer to the multimedia help system in the Tracker software .
Testing . * Heart rate monitor only available in the USA . 1 . If necessary, attach the Tracker Freedom transmitter to the Polar Heart Rate monitor by sliding the transmitter over the strap . 2 . Push the “On” button to enable communication with the Tracker Freedom Receiver...
X-ray machines . Can I block the signal during testing? Unlike infrared systems, Tracker Freedom is not based on line of sight, so standing between the instrument and the receiver should not interfere with the signal, provided you are within the operational distance .
Page 23
18 to 24 months . The Strap should be replaced at that time . You can contact JTECH Medical Customer Service to order a replacement . Do I have to buy replacement Polar Heart Rate Straps from JTECH Medical or can I buy it from any supplier? The Polar T31 non-coded Heart Rate Strap can be purchased from any supplier, or you can contact JTECH Medical Customer Service to order a replacement Strap .
Software CD that came with your system . Cannot press the “On” Packing material has Tracker Freedom devices are button as there is a rubber not been removed . packaged with a small rubber circlet piece around the button .
Tracker Freedom devices have no associated methods of preventative inspection . Maintenance Tracker Freedom devices are not user serviceable and do not include a service manual . For any service including maintenance, repair, and calibration, contact JTECH Medical Customer Support at 1-800-985-8324 or 1-(385) 695-5000 .
Product Registration Please register your Tracker Freedom System as soon as possible . Your registration ensures that you have easy access to JTECH Medical Customer Service and Support . Software registration is required to receive your site key, which is necessary to run the software .
27) . Y ou will be charged for any hardware issues (repair, replacement, shipping, etc .) after the initial warranty time period . You can buy extended warranties for your Tracker Freedom hardware . Please contact JTECH Medical Customer Service for more information on JTECH Guardian Hardware Maintenance plans .
Notice: Hardware Limited Warranty Tracker Freedom Hardware is designed to perform reliably and provide long lasting service . Should the product fail to work properly within The designated warranty period, JTECH will, at its option, repair or replace the product with a new or reconditioned unit at no charge .
Page 30
Wireless Receiver (9RF001) Used to send and receive wireless transmissions to/from Tracker Freedom instruments . Technical Specifications Dimensions 11 .4 cm x 4 .1 cm x 2 cm (4 .5 in x 1 .6 in x 0 .8 in) Weight 0 .04 kg (0 .08 lb)
Page 40
Specified Power Supply (Battery Charger) (PW005*) The Specified Power Supply (Battery Charger) is used individually, or with the Daisy Chain, for charging your Tracker Freedom devices . (*power supply connection may vary according to the country shipped to) Technical Specifications Dimensions 7 .8 cm x 5 .2 cm x 3 .5 cm (3 .1 in x 2 .0 in x 1 .4 in)
Appendix - Tracker Freedom Instruments Wireless receiver – Used to send and receive wireless transmissions to/from Tracker Freedom instruments . (9RF001) Wireless Foot Switch – Used for entering data, and moving to the next test . (9RF102) Wireless Dual Inclinometers – Used to convey functional abilities concerning range of motion (ROM) .
Guidance and manufacturer’s declaration - electromagnetic emissions The Tracker Freedom System is intended for use in the electromagnetic environment specified below . The customer or user of the Tracker Freedom System should assure that it is used in such an environment .
Page 47
Guidance and manufacturer’s declaration - electromagnetic immunity The Tracker Freedom System is intended for use in the electromagnetic environment specified below . The customer or user of the Tracker Freedom System should assure that it is used in such an environment .
Page 48
Guidance and manufacturer’s declaration – electromagnetic immunity The Tracker Freedom System is intended for use in the electromagnetic environment specified below . The customer or the user of the Tracker Freedom System should assure that it is used in such an environment .
Page 49
Recommended separation distances between portable and mobile RF communications equipment and the Tracker Freedom System The Tracker Freedom System is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled . The customer or the user of the Tracker...