Troubleshooting - Weatherdock easyTRX2S Series Manual

Class b ais cs transceiver, stand 1.8
Hide thumbs Also See for easyTRX2S Series:
Table of Contents

Advertisement

Available languages

Available languages

9

TROUBLESHOOTING

Problem
Unable to
connect to
easyTRX2S
No data output not connected
Entering MMSI
not possible
Weatherdock AG
Cause
USB cable connected
correctly?
Device configured
properly?
MMSI used before?
Sigmundstraße 180
Tel.: +49 911 376638 30
Solution
Install the Windows driver for
the USB serial interface (FTDI)
from the internet. (For
Windows select the
„recommended" driver
installation).
The driver is also contained on
the CD and will be installed
automatically.
Repeat configuration, if
necessary contact your service
partner
Check connection; are cable
colors correct? Is the data
output of the easyTRX2S device
connected with the data input
of the plotter?
Is the data rate of the NMEA
port of the plotter correct?
(standard value 38400 baud!)
The MMSI cannot be
programmed twice. The device
must be sent back to reset the
MMSI.
Please ask your service partner
for detailed information.