2506 Polycom Ring Detector
Installation Guide
Order Codes
2506
Document 90-00082J
2019-10-30
Page 1
Polycom Ring Detector
Algo Communication Products Ltd
4500 Beedie St Burnaby BC Canada V5J 5L2
www.algosolutions.com
(604) 454-3792
support@algosolutions.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2506 and is the answer not in the manual?

Questions and answers

Summary of Contents for Algo 2506

  • Page 1 2506 Polycom Ring Detector Installation Guide Order Codes 2506 Polycom Ring Detector Document 90-00082J Algo Communication Products Ltd (604) 454-3792 2019-10-30 4500 Beedie St Burnaby BC Canada V5J 5L2 support@algosolutions.com Page 1 www.algosolutions.com...
  • Page 2: Table Of Contents

    Table of Contents ABOUT THE ALGO 2506 POLYCOM RING DETECTOR ................3 GETTING STARTED - QUICK CONFIGURE & TEST ..................4 ALGO SIP ENDPOINT WEB INTERFACE CONFIGURATION ................ 5 8128/8138 W ......................6 ONFIGURATION 8180 W ........................7 ONFIGURATION 8180G2 W ........................
  • Page 3: About The Algo 2506 Polycom Ring Detector

    Algo SIP endpoint. Only one compatible Algo SIP Endpoint can be connected directly to the 2506 Polycom Ring Detector at a time. However, any of the four devices can relay a signal to additional devices via the relay output connections on the back or via multicast.
  • Page 4: Getting Started - Quick Configure & Test

    Ensure that a PoE port is used for power. 4. Plug one end of the coiled handset cord into the RJ jack on the 2506 and the other end into the HEADSET jack on the Polycom phone.
  • Page 5: Algo Sip Endpoint Web Interface Configuration

    Configuration The compatible Algo SIP Endpoint web interface should be configured before any wiring connections are made to avoid damaging the 2506. Connect the Algo SIP Endpoint to the network via an Ethernet cable at the back of the device. Ensure that a PoE port is used for power.
  • Page 6: 8128/8138 Web Configuration

    For 8128G2/8138 please follow the instructions below. • Set the “Relay Input Mode” to “Relay Normally Open”. • Select desired flash pattern. Document 90-00082J Algo Communication Products Ltd (604) 454-3792 2019-10-30 4500 Beedie St Burnaby BC Canada V5J 5L2 support@algosolutions.com Page 6 www.algosolutions.com...
  • Page 7: 8180 Web Configuration

    Set the “Speaker Terminal Function” to “Relay Input”. • Ensure that “Relay Input Polarity” is set to “Normally Open Contact”. Other configuration options can be set as desired. Document 90-00082J Algo Communication Products Ltd (604) 454-3792 2019-10-30 4500 Beedie St Burnaby BC Canada V5J 5L2 support@algosolutions.com Page 7 www.algosolutions.com...
  • Page 8: 8180G2 Web Configuration

    Set the “Relay Input Mode” to “Relay Normally Open”. • Ensure that “Action” is set to “Play Tone”. Other configuration options can be set as desired. Document 90-00082J Algo Communication Products Ltd (604) 454-3792 2019-10-30 4500 Beedie St Burnaby BC Canada V5J 5L2 support@algosolutions.com Page 8 www.algosolutions.com...
  • Page 9: 8186/8188/8189/8301 W Eb Configuration

    Set the “Relay Input Mode” to “Relay Normally Open”. • Ensure that “Action” is set to “Play Tone”. Other configuration options can be set as desired. Document 90-00082J Algo Communication Products Ltd (604) 454-3792 2019-10-30 4500 Beedie St Burnaby BC Canada V5J 5L2 support@algosolutions.com Page 9 www.algosolutions.com...
  • Page 10: Wiring Connections

    20 feet (indoor only) due to low audio levels. 2. As per the following table, connect the wires from the 2506 to the relay input (speaker output on 8180) on the device of choice: Note: The pin polarity/placement varies between devices.
  • Page 11 8128 SIP Strobe Light • 2506 “+” to Pin 2 • 2506 “-” to Pin 1 8128 SIP Strobe Light (G2) 8138 SIP Strobe Light • 2506 “+” to Pin 4 • 2506 “-” to Pin 3 8180 SIP Audio Alerter •...
  • Page 12 8186 SIP Horn Speaker • 2506 “+” to Pin 4 • 2506 “-” to Pin 3 8188 SIP Ceiling Speaker • 2506 “+” to Pin 1 • 2506 “-” to Pin 2 8189 SIP Ceiling Speaker • 2506 “+” to Pin 1 •...
  • Page 13 Ensure that a PoE port is used for power. 4. Plug the coiled handset cord into the RJ jack of the 2506. 5. Plug the other end of the handset cord into the HEADSET jack of the Polycom VVX phone.
  • Page 14: Triggering Multiple Devices

    Algo SIP Endpoint will trigger additional visual alerts on the 1128. *Except 8180G2 (since this device requires the shared relay input/output port to be configured as an input when used with the 2506, so no output is available). Please contact Algo support for further information. Document 90-00082J...
  • Page 15: Testing

    Testing Call the Polycom VVX phone to activate the Algo SIP endpoint. Ensure only one alerting device is connected directly to the 2506 at a time. Troubleshooting Wiring Connections To verify that the Algo SIP Endpoint is powered and configured correctly, short the wire pair on the input of the alerting device and see if an audio/visual alert is triggered.