Download Print this page

Sony BKP-5090 Installation And Maintenance Manual page 16

Camera upgrade board

Advertisement

1-5. Modifying VA-163 Board
1-5. Modifying VA-163 Board
The following are not supplied with the unit. Get them ready.
Description
Res, chip, metal 3.3 kZ
Res, chip, metal 15 kZ
Res, chip, metal 0 Z
1. Remove the VA-163 plug-in board from the camera.
2. Solder and short-circuit between the base and emitter of Q212, Q312 and Q412 respectively.
3. Desolder the following thirteen conponents.
R204, R220, R228, R305, R320, R328, R404, R420, R428
C40, C207, C307, C407
4. Solder a 3.3 kZ metal film resistor at the traces of R228, R328 and R428 respectively.
5. Solder a 15 kZ metal film resistor at the traces of R204, R305 and R404 respectively.
6. Solder a 0 Z metal film resistor as R493 at the trace of C40.
7. Place the supplied A label onto the VA-163 board panel as shown in the figure.
8. Perform adjustment in Section 2-2-7 or 2-3-8 "5 MHz Modulation Adjustment."
A label
4
3
VA
A
1-6 (E)
Q'ty
Sony Part No.
3
1-218-704-11
3
1-218-720-11
1
1-216-295-11
2
1
A
A
B
B
R204
Q212
R228
C
C
R220
R305
Q312
D
D
R328
R320
R404
Q412
E
E
R428
R420
F
G
VA-163 (A SIDE)
1
2
3
C40
C207
C307
C407
F
G
VA-163 (B SIDE)
4
BKP-5090

Advertisement

loading