. S408 (MARKER REMOTE/LOCAL SEL)
Selects either the HDCU-F950 or the RCP/MSU con-
nected outside in order to control the aspect marker and
skin gate signal to be inserted in the LINK A MONITOR
output signal and in the HD SDI output signal that are
output from the MONI connector on the rear panel.
REM : Control is performed by RCP/MSU etc., con-
nected outside.
LOC : Control is performed by the switches (S402,
S403, S409 and S410) on the AT-149A board.
Factory setting : REM
. S409 (MARKER)
When S408 on the AT-149A board is set to LOC, this
switch enables selection whether the ASPECT MARK-
ER signal is inserted or not in the LINK A MONITOR
output signal and in the HD SDI output signal that are
output from the MONI connector on the rear panel.
ON : Inserted
OFF : Not inserted
Factory setting : OFF
. S410 (MODULAT)
When S408 on the AT-149A board is set to LOC, this
switch enables selection whether the LINK A MONI-
TOR output signal and HD SDI output signal that are
output from the MONI connector on the rear panel,
receive the aspect modulation processing or not.
ON : Processing is ON
OFF : Processing is OFF
Factory setting : OFF
. S411 (RCP-PORT)
Not used.
Factory setting :
(
position)
. S412 (SYNC OUT HD/SD)
Selects the type of the SYNC signal to be output from
the SYNC OUT connector on the rear panel.
HD : HD SYNC signal output
SD : SD SYNC signal output (not supported)
Factory setting : HD
. S413
Not used.
Factory setting :
(
position)
1-8 (E)
indicates the switch lever
indicates the switch lever
. S414 (FIBER/COAX-1/COAX-2 SEL)
When S423-8 on the AT-149A board is set to ON, select
the camera signal reception mode of the HDCU-F950.
When S423-8 on the AT-149A board is set to OFF
(factory setting), the signal is connected by the normal
optical/electrical composite cable.
FIBER : Connection by normal optical/electrical
composite cable
COAX-1 :One-way connection using a BNC cable
(not supported)
COAX-2 :Bi-directional connection using two BNC
cables (not supported)
Factory setting : FIBER
. S416 (REF-10F-BB) (NTSC only)
Sets this switch when the multi frame is going to be
locked using the 10F-BB signal (SMPTE318M) as a
reference signal.
ON : Sets the 10F-BB signal as reference.
OFF : When the 10F-BB signal is not input to REFER-
ENCE.
Factory setting : OFF
. S417 (CONVERSION DELAY) (not used)
Selects the phase difference between the HD-SDI output
signal and the SD reference signal input.
90H :
Phase difference equivalent to 90H lines of
HD signal.
1FRAM : Unity phase mode
Factory setting : 90H
. S418 (FIELD FREQUENCY SEL)
. S419 (INTR/PROG/540P SEL)
When S420 on the AT-149A board is set to the position
other than REMOTE, sets the format of the signal that is
output from the LINK A, LINK B OUT1 and 2 connec-
tors on the rear panel.
n
The MULTIFORMAT setting of the camera side shall
have the same setting too.
HDCU-F950 IMM