Sharp VC-MH705HM/LM Service Manual page 13

Table of Contents

Advertisement

VC-MH705HM/LM
www.freeservicemanuals.info
VC-MH815HM/LM,MH85HM
VC-MH715HM,MH835HM
ADJUSTMENT OF PB Level Confirmation
Measuring
Osiloscope
instrument
Mode
Playback
Cassette
Self-recorded/Playback tape
Test point
VIDEO OUT port
(75Ω terminal)
VIDEO
Colour Bar
Specification
Check place 1.
(1±0.2Vp-p)
1.0Vp-p
ADJUSTMENT OF S-PICUTRE Confirmation
Measuring
Osiloscope
instrument
Mode
Recorded/Playback
Cassette
Self-recorded/Playback tape
Test point
VIDEO OUT
VIDEO
mono-sco
Receive the mono-sco.
Confirmation : make sure no black split at the mono-sco
picuture during the self-Rec PB when the S-PICTURE is
ON with the S-PICTURE ON/OFF,make sure the pinture
level at the wedge part is change.
(S-PICUTRE ON - about 260 line)
(S-PICUTRE OFF about 240 line)
Measure the picture out-
put port using the 75Ω
terminal Osiloscope and
confirm the diagram same
as the left diagram.
~ V:200mV/div
H:20µsec/div
Digitized in Heiloo the Netherlands
HIFI Audio Circuit ADJUSTMENT
ADJUSTMENT OF EE Level Confirmation HIFI
Lch, Rch
Measuring
Voltmeter
instrument
Mode
EE
Cassette
Optional
Test point
AUDIO OUT
VIDEO
Optional
AUDIO
AUDIO IN at 1KHz -3.8dBs
Specification
-3.8±2dBs
ADJUSTMENT OF PB Level Confrimation HIFI
Lch, Rch
Measuring
Voltmeter
instrument
Mode
Playback
Cassette
Alignment Tape VRO-CBFF
Test point
AUDIO OUT
VIDEO
Optional
AUDIO
Optional
Specification
-3.8±2dBs
~ For this item, variable the tracking switch, and confirm
the changing of the normal mode.
ADJUSTMENT OF HIFI Lch, Rch Sela Rec/PB
Level Confirmation HIFI Lch, Rch
Measuring
Voltmeter
instrument
Mode
Recorded/Playback
Cassette
Self-recorded tape
Test point
AUDIO OUT
VIDEO
Optional
AUDIO
AUDIO IN at 1KHz -3.8dBs
Specification
-3.8±2dBs
32
6/17/2019
Not for sale!

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vc-mh715hmVc-mh815hm/lmVc-mh85hmVc-mh835hm