Download Print this page

Installation Procedure - BRP EVINRUDE ICON Series Instructions Manual

Accessory power relay kit
Hide thumbs Also See for EVINRUDE ICON Series:

Advertisement

Available languages

Available languages

ICON ACCESSORY POWER RELAY KIT
3
2
4
5
ICON ACCESSORY POWER RELAY KIT
The
ICON
Accessory
P/N 765296, must be used to provide power to
boat accessories that require switched B+.
This kit is used in place of connecting
accessories to the "A" terminal of the key switch.
Connect accessories to the terminal block
provided with the accessory power relay kit.
Connecting accessories to the "A" terminal of the
key switch can cause low current, resulting in
erratic operation of the remote control system.
Accessories connected to the accessory power
relay should not exceed 7 amps.
Installation requires:
• Accessories connected to the accessory
power relay should not exceed 7 Amps.
• No more than one accessory power relay kit
installed on the ICON network.

INSTALLATION PROCEDURE

Refer to the ICON System Quick Connection
Guide, P/N 764953 for ICON System Diagram.
Disconnect the battery cables at the battery.
Select an appropriate mounting location within
25 ft. (7.6 m) of the ICON network hub.
The accessory power relay mounting location
must provide:
• protection from the weather
• access for cable connections and wiring
2 of 5
1
6
007940
Power
Relay
Kit,
Ref
P/N
765296 ACCESSORY POWER RELAY KIT
1
*HARNESS
2
*POWER CABLE
3
586224 *RELAY
4
514766 *FUSE, 10 Amp, Type ATC/ATM mini
5
776708 *TIE STRAP, Mounting
6
765295 *TERMINAL BLOCK, 20 Amp
Optional Buss Cable Extensions
764944 BUSS CABLE, Extension 1 ft. (0.3 m)
764945 BUSS CABLE, Extension 2 ft. (0.6 m)
764946 BUSS CABLE, Extension 4 ft. (1.2 m)
764947 BUSS CABLE, Extension 10 ft. (3.05 m)
764948 BUSS CABLE, Extension 15 ft. (4.57 m)
764949 BUSS CABLE, Extension 20 ft. (6.1 m)
765052 BUSS CABLE, Extension 25 ft. (7.6 m)
The accessory power relay kit can be attached to
an existing boat harness with tie straps, or can
be mounted on a flat surface using mounting tie
straps provided in the kit.
Position the harness and relay. Mark two
mounting positions 9.5 inches (241 mm) apart.
Drill two (2) 9/64 in. (3.57 mm) holes to mount
relay and harness.
Install harness and relay with two mounting tie
straps as shown.
2
1. Harness and relay
2. Mounting tie straps
Position the terminal block. Mark mounting tabs
to install terminal block. Drill two (2) 9/64 in. (3.57
mm) holes to mount terminal block.
Name of Part
007908
Qty
1
1
1
1
1
6
1
AR
AR
AR
AR
AR
AR
AR
1
2

Advertisement