ICON GATEWAY MODULE AND CABLE KIT
1
4
ICON GATEWAY MODULE
The ICON gateway module provides network
data to the NMEA 2000 network and I-Command
gauges.
The gateway module receives power from the
network power cable. When the gateway is
powered and receiving data from the network the
LED on the gateway module turns ON.
1
1. LED on gateway module
The gateway module provides fuel level
monitoring for up to four fuel tanks when
connected to fuel level senders.
IMPORTANT: Do not connect gateway module
to other types of fluid level senders. Refer to the
current I-Command Installation Guide for ac-
cessory fluid level sensors.
2 of 5
3
2
5
007941
007913
Ref
P/N
764922 GATEWAY MODULE and CABLE KIT
1
764920 *GATEWAY MODULE
2
764945 *BUSS CABLE, Extension 2 ft. (0.6 m)
Optional Buss Cable Extensions
764944 BUSS CABLE, Extension 1 ft. (0.3 m)
764946 BUSS CABLE, Extension 4 ft. (1.2 m)
764947 BUSS CABLE, Extension 10 ft. (3.05 m)
764948 BUSS CABLE, Extension 15 ft. (4.57 m)
764949 BUSS CABLE, Extension 20 ft. (6.1 m)
765052 BUSS CABLE, Extension 25 ft. (7.6 m)
3
502526 *BUTT CONNECTOR, Heat shrink
4
764151 *T-CONNECTOR, Single
5
764161 *BACKBONE CABLE, NMEA 2000

INSTALLATION PROCEDURE

Refer to the ICON System Quick Connection
Guide, P/N 764953 for ICON System Diagram.
Disconnect the battery cables at the battery.
Select an appropriate mounting location within
25 ft. (7.6 m) of an ICON network hub.
The mounting location must provide:
• protection from the weather
• access for cable connections and wiring
• a flat surface which is rigid enough to prevent
gateway module movement
Position the gateway module. Mark mounting
tabs to install gateway module.
1. Mounting tab
Drill two 9/64 in. (3.57 mm) holes to mount
gateway module.