ENGINE OIL LEVEL CHECK/CHANGE

CHECK
Place the engine on a level surface.
Remove the oil filler cap [1] and check the oil level
shown into the oil filler neck [2].
If the oil level is low, fill with recommended oil to the
upper level of the oil filler neck (page 3-3).
Check that the oil filler packing [3] is in good condition,
replace it if necessary.
Install and tighten the oil filler cap securely.
CHANGE
Place the engine on a level surface and place a suitable
container under the drain plug bolt [1].
Remove the oil filler cap [2], drain plug bolt, and drain
plug washer [3] and drain the oil into a suitable
container.
Please dispose of used oil in a manner that is
compatible with the environment. We suggest you take
used oil in a sealed container to your local recycling
center or service station for reclamation. Do not throw it
in the trash, pour it on the ground, or pour it down a
drain.
Used engine oil contains substances that have
been identified as carcinogenic. If repeatedly left in
contact with the skin for prolonged periods, it may
cause skin cancer. Wash your hands thoroughly
with soap and water as soon as possible after
contact with used engine oil.
Install the drain plug bolt with a new drain plug washer
and tighten it to the specified torque.
TORQUE: 18 N·m (1.8 kgf·m, 13 lbf·ft)
Add the specified amount of recommended oil into the
SAE 10W - 30 is
engine.
recommended for
general use. Other
OIL CAPACITY:
viscosities shown in
GX120: 0.56 Liter (0.59 US qt, 0.49 Imp qt)
the chart may be
GX160: 0.58 Liter (0.61 US qt, 0.51 Imp qt)
used when the
GX200: 0.60 Liter (0.63 US qt, 0.53 Imp qt)
average
temperature in your
RECOMMENDED OIL:
area is within the
SAE 10W-30
recommended
range.
API service classification: SJ or higher
After adding the oil, check the oil level.
Check that the oil filler packing [4] is in good condition,
replace it if necessary.
Install and tighten the oil filler cap securely.
Make sure there are no oil leaks.
MAINTENANCE
[1]
[3]
[2]
[4]
[1]
SAE VISCOSITY GRADES
AMBIENT TEMPERATURE
[2]
[3]
3-3