Air cooled liquid chillers and heat pumps (29 pages)
Summary of Contents for Accorroni HUB RADIATOR PACK CF Series
Page 1
REV_08/10/2018 Factory made high efficiency integrated hybrid system patented heat pump with direct exchange refrigerant / water to produce DHW, heating and air conditioning HUB RADIATOR PACK CF...
A2B Accorroni E.G. Srl in against third parties. - The A2B Accorroni E.G. Srl is responsible for the conformity of its product to the laws, directives and construction standards in force at time of marketing.
The products of the HUB RADIATOR PACK CF series thanks to individual components, under reserve of an installation realized to the patented direct exchange capacitors can reach rule of art and in mechanical, chemical and thermal stress high standards of energy efficiency and SCOP.
Table 1 - Specifications Cables HUB RADIATOR PACK CF Models Connection cable power supply Connection cable supply Cable Cable magneto thermal STB C-1-2 Pb3 - STB QE indoor unit external unit Section Section Section Section Type HR 3.0 2,5 mm 2,5 mm 1.50 mm 2 x (0,75 mm 2 x 2)
PIPE CONNECTIONS PIPE CONNECTIONS (CUT) (BURR REMOVAL) Fig. 1 Fig. 2 PIPE CONNECTIONS PIPE CONNECTIONS (FLARING) (FIXING) Fig. 3 Fig. 4 3. OUTDOOR UNIT INSTALLATION 3.1 GENERAL INDICATIONS When choosing the installation position, respect carefully the following indications: Make sure that the difference between the INTERNAL UNIT and the UNIT OUTSIDE is not greater than 5.0 m.
- If the appliance must be suspended from a wall external, the To avoid the above, the internal assembly and the tubes, placed support must comply with the technical specifications. between internal and external group, must be tested for leaks The wall where the unit is to be installed must be in bricks or and purged to remove non-condensing elements and moisture material of similar consistency, otherwise it must be reinforced.
Fig. 7 Fig. 8 WARNING! To make sure to perform the procedure of emptying with the group in COLD MODE Indicator of pressure pressure gauge valve Close Open Cylinder gas R410A Electronic Vacuum pump Scale 3.7 RECOVERY PROCEDURE - Connect a low pressure gauge with a hose to the - When the pressure of the pressure gauge goes from 0 service port of the gas valve.
4. INSTALLATION OF INDOOR UNITS Fig. 9 Always install the accumulator inside the building to be heated away from atmospheric agents and inside a room a controlled temperature. Make sure the wall on which the indoor unit will be installed able to support the entire weight of the system.
4.2 TECHNICAL DATA INTERNAL UNIT PATENTED HUB RADIATOR PACK CF Model U.M. PACK CF 3.0 PACK CF 8.0 Electronic Circulator Type Wilo Yonos Pico 25/18 Water accumulation content Max electronic circulator capacity Max electronic pump head Electronic circulator electric absorption 4-75 TSafety valve calibration Expansion vessel volume...
Page 12
B) Once the position of the fasteners has been marked, make a G) Proceed with the connection of the flow and return appropriate holes for inserting wall plugs to choose based on the of the heating system using 3/4 ”fittings weight of the indoor unit in operation and according to the structural type of the wall.
exhaust fumes the devices put the boiler in safety and on the LCD display shows the flashing code E14. It is absolutely forbidden to tamper with and / or exclude them safety devices. In the event of repeated shutdowns of the boiler it is necessary have the air intake / flue gas exhaust ducts checked, which Terminal may be blocked or inadequate for the disposal of fumes in the...
POSITIONING OF TERMINALS FOR "FORCED DRAFT" APPLIANCES (extracted from the UNI 7129 standard) Distance Units heating power Position of the unit 16 - 35 kW in mm Under window Under ventilation opening Under gutter Below balcony (1) From an adjacent window From an adjacent ventilation opening From vertical or horizontal pipes or drains (2) From the corner of the building...
For each 90 ° bend added the maximum allowed length must be If the keys are released before the end of the cycle time, the decreased by 1.5 meters. For each 45 ° bend added the maximum boiler continues to operate normally. allowed length must be decreased by 1 meter.
Page 16
Parameter Valori impostabili Valori di default Note 0 = instantaneous 1 = with kettle thermostat P01 Boiler type selection 0 ÷ 8 2 = with kettle temperature probe 3 = heating only 0 = natural gas P02 Gas type selection 0 - 1 1 = LPG 0 = flow switch...
4.7 ADAPTATION TO USE OF OTHER GASES AND BURNER REGULATION MANU (“P14” = 0): la caldaia esegue 5 tentativi di accensione The boilers are produced for the type of gas specifically alla potenza di accensione indicata nel parametro “P31”. requested when ordering, which is shown on packing plate and on the boiler technical data plate.
AUTO ADJUSTMENT The message "P0" appears on the display and the card is ready for set the value of O2 to the minimum power. ” Is used to switch between the Power / O2 menu (for the “ cycle time). ”...
- the correct installation of the boiler according to the instructions - check the integrity of the boiler safety devices in general; contained in this booklet. If the device is not able to power - control of the absence of water leaks and absence of oxidation function properly and in the absence of danger to people, of boiler fittings;...
5. ELECTRICAL CONNECTION DIAGRAMS 5.1 ELECTRICAL DIAGRAM HUB RADIATOR PACK CF 3.0 (boiler switch) I E/I (switch summer Winter) SUMMER WINTER Heat pump only operation By setting the IC button to OFF the system will work with only the heat pump and the boiler resistance will never work.
5.2 ELECTRICAL DIAGRAM HUB RADIATOR PACK CF 8.0 (boyler switch) I E/I (switch winter/ summer) SUMMER WINTER Heat pump only operation By setting the IC button to OFF the system will work with only the heat pump and the boiler resistance will never work.
6. TECHNICAL AND DIMENSIONAL CHARACTERISTICS 6.1 DIMENSIONS external moto- external moto evaporating unit evaporating unit Booster Booster HR 3.0 HR 7.8 Booster U.E. HR 3.0 U.E. HR 7.8 Values in mm ESTERNA BOOSTER HR 3.0 6.5 CARATTERISTICHE PRESTAZIONALI UNITÀ ESTERNA BOOSTER HR 7.8 6.2 PERFORMANCE CHARACTERISTICS OUTDOOR UNITS BOOSTER HUB RADIATOR PACK CF BOOSTER HR 3.0 BOOSTER HR 7.8...
Page 23
10,32 10,00 9,70 9,40 9,09 8,75 3,95 3,83 3,72 3,60 3,48 3,35 BOOSTER HR 3.0 BOOSTER HR 7.8 C.O.P. Potenza elettrica assorbita kW C.O.P. Water flow temperature heating °C Temperatura mandata acqua riscaldamento °C Water flow temperature heating °C Model °C Model °C...
6.3 BOILER DIMENSIONS HUB RADIATOR PACK CF 32 67 C Domestic hot water outlet (not used) F Cold water inlet (not used) R Heating system return G Gas inlet RS Drain and drain cock safety valve SI Siphon inspection cap RC Loading tap M Heating system delivery 6.4 BOILER HYDRAULIC DIAGRAM HUB RADIATOR PACK CF...
6.5 TECHNICAL FEATURES BOILER HUB RADIATOR PACK CF TECHNICAL FEATURES Nominal power Equipment category II2H3P Minimum pressure of the heating circuit Maximum pressure of the heating circuit Minimum DHW circuit pressure Maximum pressure of the sanitary circuit Domestic hot water flow rate l/min Power supply - Voltage / Frequency 230 - 50...
7. CIRCULATOR HUB RADIATOR PACK CF 8.2 HYBRID OPERATION, HEAT PUMP WITH INTEGRATION WINTER BOILER The IC key (boiler switch) must be set to ON, the I E / I button (summer / winter switch) must be set in WINTER while the digital CD controller must be set in "heating ON"...
10. START-UP 9. WARNINGS 9.1 QUALIFICATION OF THE INSTALLER Before proceeding with the commissioning of the appliance WARNING! It is foreseen by the current legislation on the you need to make sure that: - the safety conditions and all the provisions listed in this subject (law 5 March 1990 n.
11.2 DRYING AND VACUUM OF THE PLANT 12. EXTERNAL PROBE KIT Drying and high vacuum are necessary to evacuate air, humidity, and all the gases that could be in solution with The external probe kit allows to detect the external temperature compressor oil.
13. CLIMATIC MANAGEMENT OF THE HYBRID SYSTEM (WINTER PHASE) 13.1 EXAMPLE OF OPERATION WITH EXTERNAL CLIMATE PROBE HYBRID SYSTEM HUB RADIATOR PACK CF PARAMETER LIST: AR21 = 3 °C SD03 = 10 °C AR25 = 0 °C Temperature accumulation °C SD07 = 5 °C ST05 = -5 °C ST03...
13.3 CLIMATE MANAGEMENT PROCEDURE PARAMETERS SET POINT FUNCTION VALUE CF05 SET-POINT - Configuration PB2 4 °C Outside temperature ST08 SET-POINT maximum in heat pump 65,0 °C max ST03 SET-POINT winter (compressor off at external temp. 50 ° C) 65,0 °C max CLIMATE SET POINT FUNCTION SD03 Max dynamic SET-POINT increment in heat pump max variation...
Lit if at least one of the 2 water pumps 14. DIGITAL CONTROL UNIT (evaporator or pump pump condenser) is on ___________________________________________________ On if the fans they are on ___________________________________________________ On if the relative compressor is on switched on; it is flashing if the compressor it is in ignition timing 14.1 DISPLAY ___________________________________________________...
Pressure and release in programming: Regarding the use of the remote terminal (indications to the allows scrolling of folders display and the meaning of the keys) refer to the paragraphs parameters (ST, CF, etc); allows it previous. scrolling through the list of parameters. In air / air units, in case of terminal use remote equipped with In the parameter modification phase NTC probe (VICXS610), configuring par.
14.6 MAIN ALARMS ACTION RESET CAUSE MEANING Enable open collector faulty probe or resistive probe alarm Automatic output / alarm relay value out of range If the resistive value is within the Activate buzzer expected range flashing icon generic alarm display code Enable open collector probe alarm PB2...
31. Tabella Parametri SELEZIONE SOTTO-MENU 15.1 SUBMENU SELECTION LABEL SUBMENU SELECTION Displays all parameters Displays only the thermoregulation parameters ST10 Funzione unità chiller senza accumulo 0= disabilitata 1= abilitata Displays only the configuration parameters ST11 Set point minima temperatura acqua in uscita unità senza -50.0 °C accumulo in funzionamento chiller...
Page 36
ventilatore di mandata 13= Allarme termica pompa acqua condensatore CF23 Valore di pressione a 20mA / 5V 50.0 14= Flussostato condensatore CF09 CONFIGURATION ID2 CF24 Offset PB1 -12.0 12.0 °C 0 = Compressor thermal 1 °F 1 = Condensation fan thermal CF25 Offset PB2 -12.0...
Page 37
CF44 Remote display upper terminal default display CO06 Compressor ON delay from pump start / supply fan 0 = PB1 1 = PB2 CO07 Delay OFF pump / supply fan from 2 = Nothing 3 = PB4 CO08 compressor shutdown 4 = Unit real setpoint 0= Enabled 5 = Unit status...
Page 38
Evaporator water pump operation FA09 Maximum fan speed in summer Ar18 Evaporator water pump / antifreeze heaters adjustment FA10 in OFF-stand-by Minimum fan speed temperature / pressure set in -50.0 °C 0 = Disabled summer °F 50.0 1 = Activated 2 = Water pump adjustment / antifreeze heater on PB4 probe configured as room probe FA11...
dF18 4-way reverse cycle valve AL15 Low temperature / pressure differential 25.0 °C 0 = ON in cooling °F 1 = ON in heating mode 50.0 dF19 Defrost cycle temperature / pressure set -50.0 °C °F AL16 Maximum number of operations for low pressure alarm hour 50.0 analog input AL17...
Keep the exchanger by an authorized Technical Assistance Center. To know the clean implies a constant performance over time, with reduction name of the nearest Center call A2B directly Accorroni E.G. management costs. Use a vacuum cleaner to perform cleaning operations Srl or consult the site www.accorroni.it.
Page 41
Controlli Per Richiesta Primo Avviamento Hub Radiator Installatore _______________________ Progettista _______________________________ Ubicazione impianto Via ___________________________________________ N° __________________________ Città _______________________ CAP __________ Provincia ___________________________ Modello sistema installato _______________________ Matricola U.I. ___________________ Data Installazione _____________________ Tipo impianto Radiatori Raffrescamento estivo Fan-Coil Produzione ACS Pannelli radianti Riscaldamento Check list unità...
Page 42
Centro Assistenza Tecnica locale. Firma dell'installatore _______________________________________ Data _______________ A2B Accorroni E.G. s.r.l. Via d’Ancona, 37 - 60027 Osimo (An) - Tel. 071.723991 r.a. - Fax 071.7133153 web site: www.accorroni.it - e-mail: a2b@accorroni.it...
Page 43
A2B ACCORRONI E.G. s.r.l. SCHEDA PRIMA ACCENSIONE SISTEMA BREVETTATO HU RADIATOR PACK C (allegato 1) SIG.\DITTA___________________________________________________ Cod. Fisc. - P. Iva________________________________ DATI C.A.T. CITTÀ______________________________ VIA_____________________________________________________________________ CAP________ TEL._________________________ INDIRIZZO E.MAIL ______________________________________________________ DATI IMPIANTO CITTÀ_____________________________________ VIA______________________________________________________________ DATA INSTALLAZIONE___________________DATA COLLAUDO___________________ TIPOLOGIA: □ HUB RADIATOR PACK CFF 3.0 □...
Page 44
50 °C prima di effettuare le misurazioni CORRENTE ASSORBITA COMPRESSORE (A) ...._______ INSTALLATORE C.A.T. CLIENTE FIRMA FIRMA FIRMA _____________________________ _____________________________ _____________________________ A2B Accorroni E.G. s.r.l. - Via d’Ancona, 37 - 60027 Osimo (An) Tel. 071.723991 - Fax 071.7133153 - www.accorroni.it - a2b@accorroni.it...
Page 45
A2B facilities provided that the Products are put into operation within 3 months from ACCORRONI E.G .. In this case it is up to the buyer to prove that the date of leaving the A2B ACCORRONI E.G. facilities;...
Page 46
1 delle condizioni di garanzia Accorroni previo consenso dell’interessato da esprimersi in calce al “Rapporto di prima accensione”. 3) L’interessato al trattamento può esercitare i diritti di cui all’art.13 L. 675/96 rivolgendosi direttamente ad Accorroni,via d’Ancona 37 - 60027 Osimo (AN) ed in particolare a diritto a richiedere: a) la conferma di esistenza di dati personali che lo riguardano,anche se non ancora registrati,e la comunicazione in forma intelligibile dei medesimi dati a della loro origine b) la cancellazione,la trasformazione in forma anonima o il blocco dei dati trattati in violazione della legge c) l’aggiornamento, la rettifica o...
Page 47
A2B Accorroni E.G. Ltd. DECLARES that the product complies with the European Community directive in force, are classified (4 stars) according to the CEE EN 92/42 regulation which certifies the ★★★★...
Page 48
A2B Accorroni E.G. S.r.l. reserve the right to make changes without prior notice TECHNICAL MANUAL A2B Accorroni E.G. s.r.l. Via d’Ancona, 37 - 60027 Osimo (An) - Tel. 071.723991 web site: www.accorroni.it - e-mail: a2b@accorroni.it...