Kaldewei CENTRO DUO OVAL Manual page 4

Whirlsystem vivo vita

Advertisement

ALIGNMENT OF THE CASING
Before the installation of the tub models CENTRO DUO
OVAL (mod. 127-7/128-7), MEGA DUO OVAL (mod. 184-7),
CLASSIC DUO OVAL WIDE (mod. 115-7), CONO DUO (mod.
733-7/734-7/735-7) and VAIO DUO OVAL (mod. 951-7),
the casing first has to be set up on the tiled floor.
• Set up the casing in the intended place.
• Align the casing.
Align the casing in exactly horizontal position by
means of a spirit level.
• Apply a continuous silicone joint (A, approx. 10 mm
thick) to the bottom openings of the casing, as illus-
trated.
A
7
CONNECTION OF THE DRAIN AND
OVERFLOW FITTINGS
WHIRLPOOLS WITH CASING (MOD. xxx-7)
• To connect the drain and overflow fittings to the local
sewerage, place the whirlpool with its height-adjustable
feet on the supplied mounting boards.
Place, e.g., cardboard underneath the mounting
boards to protect the casing from damage.
• Carefully place the whirlpool into the casing and check
the optimum position of the siphon trap connecting
hose.
ALIGNMENT OF THE WHIRLPOOL
WHIRLPOOL WITH CASING (MOD. xxx-7)
The height-adjustable feet are preset to the correct height
in the workshop. Normally it is not necessary to adjust the
feet.
CENTRO DUO OVAL (mod. 127-7/128-7)
X = 627 mm
Y = 630 mm
MEGA DUO OVAL (mod. 184-7)
X = 587 mm
Y = 590 mm
CONO DUO (mod. 733-7/734-7/735-7)
X = 597 mm
Y = 600 mm
CLASSIC DUO OVAL WIDE (mod. 115-7)/
VAIO DUO OVAL (mod. 951-7)
X = 567 mm
Y = 570 mm
D
GB
F
I
E
PRC