Troubleshooting - Nilfisk-Advance SC DELTA Instructions For Use Manual

Table of Contents

Advertisement

SC DELTA
You have chosen the best quality and therefore deserve the best service. To avoid unnecessary dis ap point ments, you
should check the following before contacting the nearest Nilfi sk service organisation:
Symptom
Machine/pump will not start
Fuses blow
Working pressure too low
Working pressure not steady
No working pressure
Machine/pumps start and stop > Leaky hose/ pipeline/spray handle
Pump stops
Should other malfunctions occur than those mentioned above, please contact your nearest Nilfi sk service organisation.
Machine failure - see B2.6 and B2.7.
Original Instructions

Troubleshooting

Reason
> A fuse has blown
> Power/plug not connected
> Thermal switches in motor activated
(red lamp fl ashes) #5
> Thermal relay switched off (red lamp
fl ashes) #5
> Oil shortage in pump
> Installation does not correspond to the
ampere consumption of the machine
> Nozzle worn
> Wrong spray lance
> Too many users on the system
> Reduction valve of spray lance not
adjusted to max. pressure.
> Nozzle partly clogged up
> Water temperature too high
> Insuffi cient water supply to pumps
> Air in the system
> Water fi lters clogged up
> Nozzle clogged up
> No inlet water
> High pressure cock of outlet point open.
> Oil shortage in pump. Lamp fl ashes #6 • Top up with oil.
Action
• Change the fuse.
• Connect power/plug.
• Let the motor cool. Start the machine
and check that the working pressure is
not too high and that the mains voltage
corresponds to the specifi cations.
• Refi ll with oil.
• Change to an installation corresponding
to the ampere consumption of the ma-
chine at a minimum. Replace the fuse.
• Replace the nozzle.
• Replace the spray lance.
• Turn reduction valve completely counter-
clockwise.
• Clean the nozzle (see section C.3).
• Lower the temperature of the inlet water
to max. temperature (see Technical
Specifi cations).
• Check water inlet fi lter + fi lter in water
tank. If that does not solve the problem,
the water supply for the machine is
insuffi cient.
• Vent the system (see section A.7).
• Clean fi lters (see sect. C.2)
• Clean nozzle (see sect. D.3)
• Check that the shut off cock of the wa-
ter inlet is open. Check that the water
supply meets the requirements
(see section A.4)
• Close all high pressure cocks not in
use.
• Repair leak.
EN