Motorola R2010D Operator's Manual page 28

Communications system analyzer
Table of Contents

Advertisement

The following list corresponds to the step rectangles seen on the cell initiated sequence test screen, figure 5. The first
sentence following each number is the help message that will be seen if the cursor is positioned under that test square on
the R2008D/R2010D display.
R2008D/R2010D ACTIV A TEO
1. FOCC-system parameter overhead messages sent.
The R2008D/R2010D sends a continuous stream of
system parameter overhead messages to the mobile
unit under test.
2. FOCC-paging message sent. The R2008D/R2010D
sends a paging message to the mobile unit under
test. The paging message contains the mobile
telephone number entered in the initial parameters
screen.
4. Voice channel designation message sent. The
R2008D/R20 1 OD sends a message to command the
mobile to a forward voice channel.
. Alert order sent. The R20080/R2010D sends out an
alert order to command the mobile to start ringing.
8. Power level command sent. A high power level
e
command is sent by the R2008D/R2010D to the
mobile.
±Power level and handoff testing normal conversa-
tion mode. The R2008D/R2010D allows for
manual power level testing of the other power levels
possible from the mobile. Handoffs to the four
possible forward voice channels can be made. A
SAT drop test can be performed.
23
MOBILE ACTIVATED
3. Page response accepted. The R2008D/R20100 per-
ceives a valid page response from the mobile.
5. Sat accepted. The mobile and R20080/R20100 are
now on FYC
#1.
The R2008D/R20100 measures
the SAT returned by the mobile to verify that it is
the correct SAT .
7. Signaling tone accepted. The R2008D/R20IOD
detects a valid signaling tone from the mobile veri-
fying that the mobile has been alerted.
9. Power level order confirmation accepted. The
R2008D/R2010D has received an order confirma-
tion from the mobile.
11. Release signaling tone accepted. The R2008D/
R2010D has received a termination signaling tone.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R2008d

Table of Contents