5) AUTO TEST
The Auto Test Mode enables a technician to test a
cellular radio on as many channels as desired. The
R2008D/R2010D signals the radio under test as in
the sequence tests. Measured values of frequency er-
ror, output power and modulation deviation are dis-
played for each channel tested, and recorded on an
optional printer. The following sections describe how
to set up and operate the R2008D/R2010D in the
Auto Test Mode. See figure 12.
01-80356A 73
25 PIN CONNECTOR
(TO PRINTER)
R2008D
R2010D
TO
POWER
SUPPLY
CELLULAR
RADIO
50 PIN CONNECTOR
(NO CONNECTION)
MOBILE PHONE
CONTROL HEAD
0
RX
0
TX
0 RSSI
JUNCTION
BOX
AUTO TEST SETUP
FIGURE 12.