SA-PM33EE
Item
Mode Name
Description
Traverse Test
To
reliability of CD unit.
TPS
To check FF TPS for
deck.
(For more information,
refer to section 8.1.5)
Cold Start
To activate cold start ipon
next AC power up.
8.1.1.
Cassette Mechanism Self-Diagnostic Mode
Below is information of the checking of cassette deck mechanism
No.
1
C-mecha Abnormal Detection shall be
executed for DECK.
2
[
NORMAL type cassette with the recording tab
on the left side removed.
3
[
NORMAL, CrO2, METAL type cassette with
the recording tab on the right side removed.
4
[TAPE
NORMAL, CrO2, METAL type cassette (
cassette for TPS checking purposes and with
both recording tabs intact ).
5
[REC] key is pressed, after loading in a
NORMAL type cassette ( with both recording
tabs intact )
6
Self-diagnostic mode is stopped by pressing
the [n] Key.
7
To clear all the abnormalities in the memory,
press the [n] Key for more than 5 Sec while
the self-diagnostic mode is stopped.
8
To cancel the self-diagnostic mode press the
Key.
· If RAM check error occurs during microcomputer reset, COLDSTART shall be executed and all the error memory shall be
cleared during RAM initialization.
8.1.2.
EEPROM Checksum (ROM correction)
Purpose : To check for micro-processor firmware version & EEPROM check (ROM correction).
Below is the procedures for this mode.
Step 1: Enter into Doctor mode (For more information refer to section 8.1 on key operation to enter into this mode.
Step 2: Check for firmware version & EEPROM checksum.
· When entering into DOCTOR MODE the firmware version & checksum of EEPROM (if applicable) will appear on FL display.
Below is information on the EEPROM IC (Rom correction) under 3 examples:
1. When EEPROM IC is detected and there is no ROM correction:
determine
the
Operation Procedures
] key is pressed, after loading in a
] key is pressed, after loading a
] Key is pressed, after loading in a
FL Display
Micon operation & processing
Check that all DECK mechanism leaf SW is in OFF state.
FF shall be executed for 2 sec, after which STOP.
Check the following.
{ F.REC INH SW } is OFF
{ HALF SW } is ON
Reel pulse toggles between H & L.
REW shall be executed for 2 sec, after which STOP.
Check the following.
{ F.REC INH SW } is ON
{ HALF SW } is ON
Reel pulse toggles between H & L.
TPS operation is executed. Check the following.
{ F.REC INH SW } is ON
{ HALF SW } is ON
TPS signal changes.
After checking TPS, it shall STOP.
If TPS checking is completed at TAPE END, it is considered as TPS
abnormal.
REC operation shall not be executed.
Check the following.
{ F.REC INH SW } is ON
{ HALF SW } is ON
LCD shall display the abnormality item code, when the STOP key is pressed,
it shall display the abnormality item code in the following sequence.
[ TEST H 0 1] [ TEST H 0 2] [ TEST H 0 3]
At this time, all the abnormalities item in the memory is cleared and is
displayed on the LCD.[ C L E A R ] display for 1 Sec. then,[ TEST ] is
displayed.
POWER is OFF.At the next POWER ON, normal operation shall be executed.
14
Key Operation
Front Key
In doctor Mode:
1. Press [
], [1], [2] button on remote control.
To exit, press
button on main unit or
remote control.
In doctor mode:
1. Press [
] button on remote
control.
To exit, press
button on main unit or
remote control.
In doctor mode:
1. Press [SLEEP] button on remote control.
To exit, press
button on main unit or
remote control.