Dear Customer, Our compliments for having chosen a top-quality Immergas product, able to assure well-being and safety for a long period of time. As an Immergas customer you can also count on a qualified after-sales service, prepared and updated to guarantee constant efficiency of your water heater. Read the following pages carefully: you will be able to draw useful suggestions regarding the correct use of the appliance, the respect of which, will confirm your satisfaction for the Immergas product.
..........18 1.6 Electrical connection........ 7 2.6 Information menu........16 3.5 Checks following conversion to 1.7 Immergas flue systems......8 2.7 Switching off the water heater....16 another type of gas........18 1.8 Tables of Resistance Factors and 2.8 Emptying the water heater.
The place of installation of the appliance and water heater. relative Immergas accessories must have suitable In the event of malfunctions, faults or incorrect features (technical and structural) such to allow operation, turn the appliance off and contact an (always in safety, efficiency and comfortable authorised company (e.g.
1.2 MAIN DIMENSIONS. Height Width (mm) Depth (mm) (mm) Caesar 14 3 = 375 Super Caesar 17 3 = 420 CONNECTIONS DOMESTIC HOT WATER 3/4” 1/2” 1/2” Key: AC - Domestic hot water outlet AF - Domestic cold water inlet G - Gas supply V - Electrical connection 1.3 ANTI-FREEZE PROTECTION.
Attention: Immergas S.p.A. declines any respon- sibility for damage or physical injury caused by failure to connect the water heater to an efficient earth system or failure to comply with the refer- ence standards.
1.8 TABLES OF RESISTANCE FACTORS AND EQUIVALENT LENGTHS. Equivalent Equivalent length in m of concentric pipe length of Resistance Ø 60/100 pipe in m TYPE OF DUCT Factor Ø 80 Concentric pipe Ø 60/100 m 1 Intake m 7.1 Intake and Exhaust 16.5 Exhaust m 5.5 Concentric bend 90°...
It is recommended the flue exhaust. but not compulsory. Position the diaphragm on the discharge hole: Caesar 14 4 ErP: Ø 45 present inn the water heater. Super Caesar 17 4 ErP: Ø 44 present in the Upper lid thermoformed kit.
1.10 CONCENTRIC HORIZONTAL KIT 1.11 CONCENTRIC VERTICAL KIT N.B.: when the water heater is installed in areas INSTALLATION. INSTALLATION. where very frigid temperatures can be reached, Type C configuration, sealed chamber and Type C configuration, sealed chamber and a special anti-freeze kit is available that can be fan assisted.
21.5* eliminating both bends. Attention: if the installation requires a develop- take place inside the pipe and Immergas insulated ment of the flue to the discharge that exceeds the “Blue Series” flue kits must be used. recommended 12 m, due consideration must be...
1.13 DUCTING OF FLUES OR Combustion products exhaust of natural 1.19 KITS AVAILABLE ON REQUEST. TECHNICAL SLOTS. draught or fan assisted appliances in open-top • Polyphosphate dispenser kit. The polyphos- closed environments. In spaces closed on all With a specific “ducting system” it is possible phate dispenser reduces the formation of lime- to reuse existing flues, chimneys and existing sides with open tops (ventilation pits, courtyards...
USE AND MAINTENANCE In the event of work or maintenance to structures - if the appliance is not to be used for a certain near ducting or flue extraction devices and their period, disconnect the main power switch. INSTRUCTIONS accessories, switch off the appliance and on com- At the end of its service life the appliance must 2.1 CLEANING AND MAINTENANCE.
2.4 USE OF THE WATER HEATER. From this moment the water heater functions N.B.: in these conditions the water heater is Ignition (Fig. 2-1). Before ignition, check that automatically. If there is no request for DHW, it considered still powered on. the DHW inlet valve is open.
3.2 WIRING DIAGRAM. Key: B2 - Domestic hot water probe B6 - Domestic hot water flow meter B9 - Domestic hot water inlet probe DS1 - Display E3 - Ignition / detection electrode F1 - Phase fuse F2 - Neutral fuse M20 - Fan R5 - Domestic hot water temperature selector switch S2 - Stand-by / ON Button...
Solar delay timing. The water heater is set to SIT 845 Gas Valve Key: switch-on immediately after a request for DHW 1 - Coil In the case of coupling with a solar storage tank 2 - Minimum power adjustment screw positioned upstream from the water heater, it 3 - Maximum power adjustment screw is possible to compensate the distance between...
3.8 AUTOMATIC SLOW IGNITION - Check that the internal system is properly FUNCTION WITH TIMED RAMP sealed according to technical regulations in DELIVERY. force; In the ignition phase, the burner ignites at the - Check the intervention of the device against no "ignition power value"...
3.12 CASING REMOVAL. To facilitate water heater maintenance, the casing can be completely removed by following these simple instructions (Fig. 3-5): 1) Loosen the lower screws (a) that fix the lower protection grid (b) and the casing (c). 2) Widen the casing (c) pulling the sides slightly outwards.
The Burner pressure values refer to use of gas at 15°C. The adjustments should therefore,be carried out power data in the table has been obtained with Caesar 14 4 ErP. METHANE (G20) BUTANE (G30) PROPANE (G31)
3.16 KEY FOR DATA NAMEPLATE. Cod. Md Sr N° Cod. PIN Type n min. max. n min. n max. Class N.B.: the technical data is provided on the data plate on the water heater. Model Cod. Md Model code Sr N° Serial Number Check Cod.
3.17 PRODUCT FICHE (IN COMPLIANCE WITH REGULATION 812/2013). Caesar 14 4 ErP Super Caesar 17 4 ErP CAESAR 14 4 ERP SUPER CAESAR 17 4 ERP kW/h/annum GJ/annum kW/h/annum GJ/annum Parameter value Parameter value Annual electricity consumption for the Annual electricity consumption for the...
Should you wish to install an assembly, starting domestic hot water function (e.g.: water heater from the Caesar 14 4 ErP or Super Caesar 17 4 + solar thermal system). ErP water heater, use the package fiche in Fig. 3-8.
Page 28
Parameters for filling in DHW package assembly chart. Parameter Caesar 14 4 ErP Super Caesar 17 4 ErP ‘I’ ‘II’ ‘III’ * to be determined according to Regulation 812/2013 and transient calculation methods as per Notice of the European Community no. 207/2014.