Electrical Considerations
Be sure the final installation site has enough AC outlets to support the computer and the
peripherals located close to
it.
Be sure the outlets are grounded and are protected by a circuit
breaker. Be very sure the AC power available meets the electrical specifications. Refer to
Table 2-2 for the exact electrical specifications.
Specifications
Table 2·1. Environmental Specifications
Description
Specification
Operating
Temperature
5°C to 40°C (41°F to 104°F)
Non-operating
Temperature
-40°C to 65°C (-40°F to 149°F)
(without
internal
DDS-format
drive)
-40°C to 45°C
(-40°F to 113°F) (with internal
DDS-format
drive - tape media limit)
Maximum
Rate of Temperature
Change
20°C (36°F)/hour
(without
tape
media)
lOoC (18°F)/hour
(with tape media)
High Speed Fan (Activated)
30°C to 38°C (86°F to 100.4°F)
Overtemp
Warning
40°C to 48°C (104°F to 118.4°F)
Overtemp
Hardware
Shutdown
Overtemp
Warning
+2°C (~3°F)
Operating
Humidity
20% to 80% RH max wet bulb
=
26°C, non-condensing
Non-operating
Humidity
5% to 80% RH, non-condensing,
less than 30% RH/hr
rate of change
Operating
Altitude
°
to 3048 meters
(10,000 ft)
Nonoperating
Altitude
°
to 4573.2 meters
(15,000 ft)
Heat Dissipation
(max load)
1300 BTU/hr
Operating
Vibration
(random)
0.0001 g2/Hz, 5 to 350 Hz
-6dB/Octave,
350-500 Hz
0.00005 g2/Hz, 500 Hz
(~ 0.21 G
rms )
N on-operating
Vibration
(sine)
0.5g (peak), 5 to 500 Hz
Shock (nonoperating)
Edge drop from 2.5 in. above floor
Sound Power
<
37°C
=
<
45 dB(A) sound pressure
at operator's
position.
<
5.5 bels(A) sound pressure
>
37°C
=
<
50 dB(A) sound pressure
at operator's
position.
<
6.0 bels(A) sound pressure
2-2
Site Considerations