Sony Trinitron RM-W101 Service Manual page 6

Bx1s chassis
Hide thumbs Also See for Trinitron RM-W101:
Table of Contents

Advertisement

KV-BM142M70
RM-W101
2. DISPLAY OF
STANDBY (1)
FLASH COUNT
2 times
4 times
5 times
8 times
Lamp ON 300ms
Lamp OFF 300ms
3. STOPPING THE
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY (1)
indicator from flashing.
4. SELF-DIAGNOSTIC SCREEN DISPLAY
For errors with symptoms such as "power sometimes shuts off" or "screen sometimes goes off" that cannot be confirmed,
it is possible to bring up past occurrences of failure on the screen for confirmation.
[To Bring Up Screen Test]
In standby mode, press buttons on the remote commander sequentially in rapid succession as shown below:
/ Channel 5 / Volume
Display
The following screen will be displayed indicating the error count.
SELF DIAGNOSTIC
2 :
0
3 :
N/A
4 :
0
5 :
1
8 :
0
101 :
N/A
INDICATOR
Lamp OFF 3 sec.
INDICATOR FLASH
STANDBY (1)
˘
Note that this differs from entering the service mode (volume [+]).
Numeral "0" means that no fault was detected.
Numeral "1" means the number of a fault occurrence (1 ~ 255).
Diagnostic Item
+B overcurrent
V-Protect
IK (AKB)
Power Supply NG (+5V)
for Video processor
* One flash count is not used for self-diagnosis.
/ Power
/ TV
– 4 –
Flash Count*
2 times
4 times
5 times
8 times
STANDBY indicator