Download Print this page

Festo NEBM-M12G8-E S1G15 Series Instructions & Assembly page 2

Encoder cable

Advertisement

Fig. 7
9. Do not bend cables all the way to the fastening point.
Ä Mounting space A between the fastening point and bending movement is
observed.
NOTICE!
Damage to cables if the chain breaks.
Replace cables after a chain break.
NOTICE!
Malfunction and material damage due to vertically suspended cables.
The cables stretch.
Regularly check the length of the cables.
Readjust the cables if required.
5
Technical data
NEBM­M12G8­E­...­S1G15
Cable characteristic
Cable composition
Shielding
Cable diameter
D
Mounting space
A
Operating voltage range AC/DC
U
B
Bending radius
Fixed cable installation
R
Flexible cable installation
R
Ambient temperature
Fixed cable installation
Flexible cable installation
Material
Cable sheath
Electrical connection 1
Function
Connection type
Connection technology
Type of mounting
Degree of protection
Electrical connection 2
Function
Connection type
Connection technology
Degree of protection
Tab. 2 Technical data
Suitable for energy chains
[mm²]
4 x 2 x 0.14
Shielded
[mm]
6.8
[mm]
136
[V]
0 ... 30
[mm]
³ 34
[mm]
³ 68
[°C]
–40 ... +80
[°C]
–5 ... +80
TPE-U(PUR)
Field device side
Socket
M12x1 A-coded to EN 61076-2-101
Screw-type lock
IP65 In assembled state
Controller side
Plug connector
Sub-D
IP30 In assembled state

Advertisement

loading