Flo-Pod™ Hood
Instructions for use
BS\094\B\2017
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Flo-Pod and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Respirex Flo-Pod

  • Page 1 Flo-Pod™ Hood Instructions for use BS\094\B\2017...
  • Page 2: Table Of Contents

    Contents General Information ................1 Designation .................... 1 Warnings & Limitations ................1 Pre-Checks ..................... 2 Donning procedure ................. 2 Doffing procedure ................... 4 Emergency procedure ................4 Storage & Transportation................ 5 Cleaning ....................5 Sizing ...................... 5...
  • Page 3: General Information

    Important: The Flo-Pod™ hood must only be used in • At very high work rates the pressure in the Flo-Pod™ combination with the Respirex Flo-Pod™ turbo unit, no system may become negative at peak inhalation flow.
  • Page 4: Pre-Checks

    Fig. 2. Plug turbo unit power cable into battery pack Donning procedure 13. Turn on the Flo-Pod™ turbo unit using the orange switch located on the underside of the battery Note: Before beginning the donning process, ensure pack (Fig.3). IMPORTANT: To avoid a suffocation that the Flo-Pod™...
  • Page 5 14. Open neck seal fully by loosening the drawstring (Fig. 4). Fig. 6. Tighten drawstring Fig. 4. Loosen drawstring 16. The cape of the hood should be pulled downwards and adjusted until it sits evenly on the shoulders; 15. Position the hood over your head and tighten the turbo unit must be positioned a maximum distance of 4cm in front of the wearer’s chin.
  • Page 6: Doffing Procedure

    Unfasten the waist belt buckle, then remove belt and battery pack. Before being re-used with a new hood, the Flo-Pod™ turbo unit should be decontaminated according to your company procedures. Depending upon the nature and...
  • Page 7: Storage & Transportation

    The recommended temperature range for storage is The following pictogram designates the range of height -10°C to +40°C. & chest sizes suitable for use with the Flo-Pod™ hood. Store hoods in the original packaging, correct way up as Body measurements in cm.
  • Page 8 RESPIREX INTERNATIONAL LTD, Unit F Kingsfield Business Centre, Philanthropic Road, Redhill, Surrey RH1 4DP United Kingdom Tel. +44 (0) 1737 778600 Fax.+44(0) 1737 779441 www.respirexinternational.com BSI (0086), Type Examination By : Kitemark Court, Davy Avenue, Knowhill, Milton Keynes MK5 8PP...