Fitting and Installation

2. Fitting and Installation
This information in this section is important and must be observed during fitting
and installation. The units must be fitted to use.

2.1. Fitting the CTR 210

2.4. Cable and PE

Only shielded cable may be used. The shield must be connected in the casing
or the EMC clamps. The PE must be connected to the PE terminal and the PE
screw at the CTR 210 housing.
6
The CTR 210 has external
dimensions of 144 mm x 72 mm.
You need a cut off in the panel
mount with the dimensions of
138
+1,0
mm x 68
+0,7
(DIN43700). The depth is 105mm.
Release the two screws from the
mounting profile. You move the
CTR 210 from the front through
the panel mount.
Hold the unit horizontal and move
the mounting profile to the intent
screws where are they removed
before.
Please track the nut from the
mounting profile consistently good
tight.

2.2. Protection Class IP20

The CTR 210 conforms to
protection class IP20. The front
conforms IP54.

2.3. Temperature ranges

The CTR 210 can be operated in
the range –20°C to +60°C.