Philips 32PFH5500/88 Service Manual page 21

Qm15.2e chassis
Table of Contents

Advertisement

4.3.5
IR board Control Unit
Refer to
Figure
4-20,
Figure 4-21
1. Unplug the connector from the SSB.
Caution: be careful, as these are very fragile connectors!
2. Remove all the fixation screws from the IR board control
unit [1].Refer to
Figure 4-20
3. Remove the IR lens [2], IR board [3] from the
DECO_REAR_COVER. Refer to
When defective, replace the whole unit.
1
Figure 4-20 IR board removal[1]
Figure 4-21 IR board removal[2]
4.3.6
Speakers
1. Gently release the tapes that secure the speaker cables.
2. Unplug the speaker connector from the SSB.
3. Take the speakers out.
When defective, replace the both units.
for details.
for details.
Figure 4-21
for details.
1
1
19850_103.eps
3
2
19850_104.eps
Mechanical Instructions
4.3.7
WIFI module
1. Unplug the connector from the SSB.
2. Remove fixation screw that secure the WIFI module,
getntly remove the module from the set.
When defective, replace the whole unit.
4.3.8
LCD Panel
1. Remove the SSB as described earlier.
2. Remove the PSU as described earlier.
3. Remove the keyboard control panel as described earlier.
4. Remove the stand bracket as described earlier.
5. Remove the IR Board as described earlier.
6. Remove the WIFI module as earlier.
7. Remove the fixations screws that fix the metal clamps to
the front bezel. Take out those clamps.
8. Remove all other metal parts not belonging to the panel.
9. Lift the LCD Panel from the bezel.
When defective, replace the whole unit.
back to
div.table
QM15.2E LA
4.
EN 21
2015-Sep-30

Hide quick links:

Advertisement

Table of Contents
loading