crystal fires SAPHIRE Installation & Servicing Book

Decorative fuel effect gas fire, this appliance is cat i2h for use with natural gas only g20 at 20mbar in g.b. and i.e.

Advertisement

Quick Links

+
1 VALENTINES BUILDINGS
BECHERS DRIVE
AINTREE RACECOURSE
BUSINESS PARK
AINTREE
LIVERPOOL
L9 5AY
SAPHIRE
DECORATIVE FUEL EFFECT GAS FIRE
THIS APPLIANCE IS CAT I
2H
FOR USE WITH NATURAL GAS
ONLY
G20 AT 20mbar
IN G.B. AND I.E.
INSTALLATION & SERVICING
BOOK
ISSUE 1
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the SAPHIRE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for crystal fires SAPHIRE

  • Page 1 1 VALENTINES BUILDINGS BECHERS DRIVE AINTREE RACECOURSE BUSINESS PARK AINTREE LIVERPOOL L9 5AY SAPHIRE DECORATIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS CAT I FOR USE WITH NATURAL GAS ONLY G20 AT 20mbar IN G.B. AND I.E. INSTALLATION & SERVICING...
  • Page 2: Sizes Including Trim

    600mm 840 mm Floor level ‘A’minimum 300 mm from floor level to shelf height SIZES INCLUDING TRIM PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE YOU START INSTALLING THE APPLIANCE. KEEP THIS BOOKLET HANDY FOR FUTURE REFERENCE ISSUE 1...
  • Page 3 TECHNICAL DATA GAS TYPE: NATURAL GAS GAS PRESSURE: 20mbar CONNECTION 8mm TUBE INJECTOR manual control: CAT 82/380 BRAY HEAT INPUT 6.2kW HIGH 3.8kW LOW CAT 1 DATA BADGE ON FRONT BOTTOM SECTION OF APPLIANCE IMPORTANT NOTES THIS APPLIANCE IS FITTED WITH AN ATMOSPHERE SENSING DEVICE AND CAN ONLY BE FITTED IN CONJUNCTION WITH THE FOLLOWING FLUES.
  • Page 4 IRELAND. PURPOSE PROVIDED VENTILATION MUST BE PROVIDED AND MUST HAVE A MINIMUM AS STATED “(IN I.S 813 DOMESTIC GAS INSTALLATIONS-NATIONAL STANDARDS AUTHORITY OF IRELAND)” WARNING THIS APPLIANCE HAS A NAKED FLAME, AS WITH ALL SUCH FIRES IT IS RECOMMENDED THAT A FIREGUARD SHOULD BE USED FOR THE PROTECTION OF CHILDREN, THE ELDERLY AND INFIRM.
  • Page 5 CONVENTIONAL CHIMNEY A CONVENTIONAL BRICK OR STONE CHIMNEY AS USED FOR SOLID FUEL APPLIANCE WITH A MINIMUM EFFECTIVE CROSS SECTIONAL DIMENSION OF 225*225mm, WITH A MINIMUM OF 3 METERS EFFECTIVE HEIGHT. A LINED FLUE WITH A MINIMUM DIAMETER OF 125mm WITH THE FIREPLACE COMPONENTS CONFORMING TO BS 1251 A BUILDERS OPENING A MINIMUM OF 400mm HIGH AND 350mm WIDE WITH A MINIMUM DEPTH OF 150mm TO ALLOW SUFFICIENT VOLUME OF...
  • Page 6 THE RELEVANT BRITISH STANDARDS MUST BE FOLLOWED BS 5871 :PART 3 BS 5440: PART 1 AND 2 BS 6891 BS 8303 BS 1251 AND I.S 813 FOR IRELAND A BRICK CHAMBER TO THE SIZES IN FIG 2 IN AN EXISTING BRICK OR STONE CHIMNEY A 125mm MINIMUM DIAMETER FLUE LINER CONFORMING TO BS715 MAY BE USED, PROVIDING IT IS SEALED AT THE TOP AND BOTTOM OF THE EXISTING BRICK OR STONE...
  • Page 7 HEARTH NO PURPOSE MADE HEARTH IS REQUIRED WITH THIS GAS APPLIANCE PROVIDING IT IS WALL MOUNTED AT A MINIMUM HEIGHT OF 300mm TO THE SHELF HEIGHT AS SHOWN BELOW MINIMUM 300 mm SKIRTING BOARD ISSUE 1...
  • Page 8 CARE SHOULD BE TAKEN TO PREVENT ANY DAMAGE BEING CAUSED TO SURROUNDING SOFT FURNISHINGS OR DECORATION. MANY EMBOSSED VINYL WALL COVERINGS MAY BECOME DISCOLOURED IF PLACE TOO CLOSE TO THE APPLIANCE CHECK FLUE CHECK THAT THE CHIMNEY CONFORMS TO THE REQUIRED SPECIFICATIONS AS PREVIOUSLY STATED.
  • Page 9: Front Cover

    FRONT COVER THE FRONT COVER SLIDES FORWARD TO GET ACCESS TO GAS VALVE AND TEST ELBOW TO CHECK FOR PRESSURE AND SOUNDNESS. CHECKING GAS PRESSURE AND SOUNDNESS REMOVE THE PRESSURE TEST POINT SCREW FROM THE INLET ELBOW AND CONNECT PRESSURE GAUGE. TURN ON GAS TO APPLIANCE.
  • Page 10 ONLY USE FUEL PIECES STATED IN LAYOUT THE FRONT FIBRE COMES INSTALLED IN THE APPLIANCE. AND THE REAR MATRIX FITS BEHIND , ENSURE FLAT AND FLUSH TO LOCATING POINTS AS SHOWN THE SEVEN ROUND FUEL PIECES SIT WITH FLAT BASES DOWN, THE FUEL PIECES ARE LEVEL WITH THE FRONT FIBRE AND DO NOT OVERLAP ON TO THE BURNER.
  • Page 11 THE TWO SMALL FUEL PIECES SIT HORIZONTAL ON LEFT AND RIGHT AS SHOWN BETWEEN ROUND FUEL PIECES AND REAR MATRIX FRONT FUEL PIECE SITS ON ROUND FUEL PIECES WITH BRANCH LOOKING TO REAR AND TOUCHING RIGHT PILLAR ON REAR MATRIX. IT IS POSITIONED HORIZONTAL BETWEEN THE TWO SMALL PIECES ON LEFT AND RIGHT...
  • Page 12 CENTRE TOP FUEL PIECE SITS TO RIGHT OF LEFT TOP PIECE THIS TIME BRANCH IS TO THE FRONT AS SHOWN THERE SHOULD BE A GAP OF 20mm BETWEEN THE TWO TOP BRANCH FUEL PIECES RIGHT TOP FUEL PIECE SITS TO THE RIGHT OF THE CENTRE TOP PIECE THIS TIME WITH BRANCH TO REAR AS SHOWN...
  • Page 13 TEST FOR SPILLAGE CHECK FOR SATISFACTORY CLEARANCE OF COMBUSTION PRODUCTS CLOSE ALL DOORS AND WINDOWS IN THE ROOMS CONTAINING THE FIRE. TURN ON GAS FIRE AND SET THE CONTROL TO HIGH LEAVE THE FIRE BURNING FOR FIVE MINUTES AND INSERT A LIGHTED SMOKE MATCH ON A VERTICAL PLANE 50 mm DIRECTLY UNDER FRONT EDGE OF CANOPY AND 50mm FROM EITHER SIDE OF THE OPENING...
  • Page 14 SERVICING NOTES GENERAL NOTES. SERVICING SHOULD BE CARRIED OUT ANNUALLY BY A COMPETENT PERSON SUCH AS A CORGI REGISTERED PERSON IN ACCORDANCE WITH THE RELEVANT REGULATIONS, TO ENSURE THE SAFE AND CORRECT OPERATION OF THE APPLIANCE BEFORE COMMENING ANY SERVICE OR REPLACEMENT OF PARTS TURN OFF GAS SUPPLY TO FIRE AFTER SERVICING CHECK FOR GAS SOUNDNESS AT LEAST ONCE A YEAR CHECK FOR DEBRIS...
  • Page 15 LOCKNUT "B" INJECTOR RE ASSEMBLE IN REVERSE ORDER TURN ON GAS SUPPLY. CHECK FOR SOUNDNESS AND RECOMMISION THE FIRE. REPLACEMENT OXY PILOT ASSEMBLY DISCONNECT FIRE AT INLET ELBOW REMOVE FIRETRAY DISCONNECT THERMOCOUPLE AT GAS VALVE DISCONNECT GAS CONNECTION FROM PILOT ASSEMBLY REMOVE IGNITOR LEAD FROM PILOT ASSEMBLY UNDO SCREWS SECURING OXY PILOT TO FIRETRAY RE-ASSEMBLE IN REVERSE ORDER...
  • Page 16: Decorative Fuel Effect Gas Fire

    1 VALENTINES BUILDINGS BECHERS DRIVE AINTREE RACECOURSE BUSINESS PARK AINTREE LIVERPOOL L9 5AY SAPHIRE DECORATIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS CAT I FOR USE WITH NATURAL GAS ONLY G20 AT 20mbar IN G.B. AND I.E. USERS INSTUCTIONS ISSUE 1...
  • Page 17 USERS INSTRUCTIONS FOR SAPHIRE GAS APPLIANCE YOUR SAPHIRE GAS APPLIANCE IS A DECORATIVE LIVE FUEL EFFECT GAS FIRE ,DUE TO ITS NEWNESS THE FIRE MAY GIVE OFF SLIGHT SMELL FOR A SHORT PERIOD AFTER INSTALLATION .THIS IS QUITE NORMAL AND WILL DISAPPEAR AFTER A FEW HOURS OF OPERATION.
  • Page 18 HEAT INPUT HIGH 6.8Kw LOW 3.8Kw gross JET CAT82/380 BRAY PILOT SAPHIRE DECORATIVE FUEL EFFECT GAS FIRE CRYSTAL FIRES1 BECHERS DRIVE L9 5AY THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE RULES IN FORCE AND USED ONLY IN A SUFFICIENTLY VENTILATED SPACE .CONSULT INSTRUCTIONS BEFORE...
  • Page 19 COALS AND CERAMICS IF FOR ANY REASON IT IS NECCESARY TO REMOVE CERAMIC PARTS,THEN BEFORE REPLACEMENT THE BURNER SHOULD BE CHECKED THAT NO PARTICLES HAVE DEPOSITED ON THE BURNER AND IF NECCESARY VACUUM THEM CAREFULLY WITH A SOFT BRUSH ATTACHMENT ,THEN REFER TO INSTRUCTIONS FOR REPLACING CERAMICS.
  • Page 20 REAR CURVED FIBRE FITS CENTRALLY AS SHOWN ENSURE CUT OUTS ON BOTH SIDES ARE VISIBLE AS SHOWN TO ENSURE CORRECT PLANE THE TWO SMALL FUEL PIECES SIT HORIZONTAL ON LEFT AND RIGHT AS SHOWN BETWEEN ROUND FUEL PIECES AND REAR MATRIX FRONT FUEL PIECE SITS ON ROUND FUEL PIECES WITH BRANCH LOOKING TO REAR AND TOUCHING RIGHT...
  • Page 21 LEFT SMALL LOG PIECE FITS ON ANGLE JOINING REAR CURVED LOG PIECE AND FRONT FUEL PIECE AS SHOWN ENSURE BRANCH IS TO THE REAR CENTRE TOP FUEL PIECE SITS TO RIGHT OF LEFT TOP PIECE THIS TIME BRANCH IS TO THE FRONT AS SHOWN THERE SHOULD BE A GAP OF 20mm BETWEEN THE TWO TOP BRANCH FUEL...
  • Page 22 THE APPLIANCE MAY BE LIT WITH A TAPER IF THE IGNITION FAILS ,POSITION TAPER AS SHOWN AND OPERATE THE APPLIANCE AS NORMAL THEN SEEK ADVISE TO HAVE THE FAULT REPAIRED FROM A CORGI APPROVED ENGINEER taper CUSTOMER SPARE PARTS FUEL BED SAPH001 MAIN MATRIX SAPH002...
  • Page 23: Additional Instructions

    MERTIK MAXITROL REMOTE CONTROL SYSTEM ADDITIONAL INSTRUCTIONS THESE INSTRUCTIONS ARE FOR THE USE ON CRYSTAL FIRES REMOTE CONTROL RANGE OF GAS FIRES ON POSITION OFF POSITION IGNITION /PILOT POSITION FIGURE 1 OPERATION LIGHTING PROCEDURE 1. TURN KNOB A (FIGURE 1) SLIGHTLY LEFT TOWARDS THE IGNITION...
  • Page 24 OR RIGHT HAND SIDE OF THE FIRE.ENSURE THAT THE GAS PIPE DOES NOT PREVENT THE REMOVAL OF THE BATTERY HOLDER AND SENSOR OR ACCESS TO OPERATE THE GAS CONTROL KNOBS MODIFIED TECHNICAL DATA INJECTOR SIZES SUPER HEATRAVE/SLIMLINE/RUBY/LAGOON CAT 82/460 SAPHIRE CAT 82/420 JEWEL CAT 82/500 ISSUE 1...