6.
Screw the round defibrillation adapter post into the defibrillation chest post site on the posterior
of the simulator. (See figure 9.)
7.
Included with the simulator is a set of defibrillation adapters 101-054U, for use with training
cables (sold separately). See the section for supplies and replacement parts for part number
information.
8.
Attach defibrillation cables coming from the left side of the manikin labeled sternum and apex
to the LF03670AU Interactive ECG Simulator. (See figure 10.)
9.
Connect the labeled cords to the appropriate labeled holes in the top of the LF03670AU
Interactive ECG Simulator Sternum and Apex.
10.
To view the waveforms produced by the Interactive ECG Simulator, connect the 4 colored limb
leads coming from the left side of the infant simulator to the same colored snaps on the side of
the Interactive ECG Simulator. (See figure 11.)
11.
Connect the limb leads from your defibrillator/monitor to the appropriate anterior sites on the
infant simulator. (See figure 12; defibrillator shown not included.)
Figure 10
Figure 12
Figure 11