Download Print this page

Advertisement

Quick Links

C.H.A.R.L.I.E. Neonatal Resuscitation Simulator
LF01420U with ECG Simulator
LF01421U without ECG Simulator
Products by Nasco Healthcare

Advertisement

loading

Summary of Contents for Nasco Healthcare C.H.A.R.L.I.E. LF01420U

  • Page 1 C.H.A.R.L.I.E. Neonatal Resuscitation Simulator LF01420U with ECG Simulator LF01421U without ECG Simulator Products by Nasco Healthcare...
  • Page 3 About the Simulator Meeting your neonatal resuscitation program course curriculum with C.H.A.R.L.I.E., the Neonatal Resuscitation Simulator. The fully functional, manual simulator measures 19 ⁄ " (49.53 cm) from crown to heel and weighs approximately 8 ⁄ lbs. (3.86 kg). Practice all of the essentials of neonatal resuscitation with this simple simulator as well as any birthing scenario! Features •...
  • Page 4: List Of Components

    List of Components Vein System for IV Foot (shown installed) Male Genitalia Full-Term Infant Simulator Female Genitalia 2 Airways (1 normal, 1 advanced) Myelomeningocele Birth Defect Baby Powder Omphalocele Birth Defect Blood, Pint Bottle with Blood Powder (shown mixed) Umbilicus (shown installed) Carry Bag 3 cc Syringe with Needle Defibrillation Chest Insert (shown installed)
  • Page 5 Figure 1 Figure 2 Figure 3 Figure 4 Setup Caution The infant simulator is constructed with electronic components. Extreme care should be used when uti- lizing fluid capable features of the simulator, so as to not damage electronics or cause harm to users. A.
  • Page 6 Figure 6 Figure 5 Figure 7 Figure 8 B. Defibrillation Chest Insert, ECG Simulation Alternate Chest Inserts, LF01401U Non-Defibrillation Bilateral Chest Insert and LF01402U Unilateral Chest Insert, are available for purchase. To Install the Defibrillation Chest Insert and Connect Interactive ECG Simulator: Remove the wire from under the white plate in the base of the chest cavity.
  • Page 7 Figure 9 Figure 10 Figure 12 Figure 11 Screw the round defibrillation adapter post into the defibrillation chest post site on the posterior of the simulator. (See figure 9.) Included with the simulator is a set of defibrillation adapters 101-054U, for use with training cables (sold separately).
  • Page 8 Figure 13 Figure 14 Figure 15 Figure 16 C. IV Hand and Foot Both the right hand and foot are equipped with functional IV access for infusion practice. Caution The infant simulator is constructed with electronic components. Extreme care should be used when utilizing fluid capable features of the simulator, so as to not damage electronics or cause harm to users.
  • Page 9 Figure 18 Figure 17 Figure 19 Figure 20 Carefully pull the skin over the hand, taking care not to dislodge the vein tubing. (See figure 17.) Follow the same procedure for the foot. (See figure 18.) Connect the hand tubing to the foot tubing as shown.
  • Page 10 Figure 22 Figure 23 Figure 24 Figure 25 When installing the new bone, make sure it is correctly positioned in the leg cavity. (See figures 22 and 23.) Replace the skin. A light dusting of baby powder on the inside of the skin will help it to slide on easily.
  • Page 11 Figure 26 Figure 27 Figure 28 Figure 29 F. GI Figure 30 The left nostril will accept an 8 FR NG tube that will pass into a small tube embedded in the chest cavity of the infant simulator. Note: This is for tube placement only. No fluids should be infiltrated into the simulated stomach cavity.
  • Page 12 Figure 31 Figure 32 I. Defects Two different birth defects are included with the infant simulator. The omphalocele birth defect fits over the patent umbilicus. (See figure 31.) The neural tube defect fits into the hole on the back of the infant simulator.
  • Page 13 Figure 33 Figure 34 Figure 35 Figure 36 C. CPR and Defibrillation The infant simulator comes with an Interactive ECG Simulator (LF03670AU) with part number LF01420U. Any Life/form ® Interactive ECG Simulator (LF03670AU) will work with part number LF01421U. The Interactive ECG Simulator acts as the load box and can accept up to 360 joules of energy.
  • Page 14 Figure 37 Pressing any of the rhythm buttons will select that rhythm. Figure 38 To convert, select the initial rhythm to display. Press the convert button. Select the rhythm to display after conversion. This rhythm will be blinking. Shock the manikin using industry standards for infant defibrillation. The blinking rhythm will then turn solid on the Interactive ECG Simulator and will be the rhythm displayed on your defibrillator/monitor.
  • Page 15 Figure 41 Figure Figure Figure 42 Figure 43 F. Performing IV Infusions Procure a 3rd IV bag (sold separately, LF01130U). Begin with a fully pressurized system. Insert the IV needle or butterfly into a vein. Flashback will indicate a proper insertion. Attach the needle or butterfly to the tubing from the infusion solution or fluid supply Bag C using the small latex piece.
  • Page 16 Figure 44 Figure 45 Maximum capacity is approximately 5 cc. After each use, remove the umbilicus, using caution to not disconnect the pulse system tubing, and empty the reservoir with the syringe. Wipe out remaining fluid with a paper towel. Leave open to air dry.
  • Page 17: Troubleshooting

    Figure 47 Figure 48 A small amount of the supplied lubri- Figure 49 cant on the surface of the skin will prevent devices from grabbing during the procedure. Skin surfaces can become tacky with handling. Bones can be punctured multiple times.
  • Page 18: Care And Maintenance

    Care and Maintenance Several of the infant simulator components are completely washable and may be immersed in water. Perform the below care and maintenance procedures after each use. Ensure all medical devices and appliances are removed from the infant simulator after each use. Remove all components (hand and foot skins, umbilicus, birth defects, lung plate, and airway).
  • Page 19 Additional Supplies/Replacement Parts 101-054U Laerdal Adapter Posts LF01401U Non-Defib Bilateral Chest Insert LF01402U Unilateral Chest Insert Manual Defib Site Posts LF01403U Normal Airway LF01404U IV Hand Skin and Vein LF01405U IV Foot Skin and Vein LF01406U Cannulating Umbilicus (no pulse system) Marquette Physio Adapter Posts...
  • Page 20 Other Available Simulators LF00714U Clots and Hemorrhages Set LF01400U Newborn Nursing Skills and ALS Simulator LF01280U Micro-Preemie Simulator, Light LF01281U Micro-Preemie Simulator, Dark LF01400U LF01280U LF00714U 901 Janesville Avenue, P.O. Box 901 Fort Atkinson, Wisconsin 53538-0901 1.800.558.9595 eNasco.com • E-mail: lifeform@eNasco.com COPYRIGHT ©...

This manual is also suitable for:

C.h.a.r.l.i.e. lf01421u