Download Print this page

Operation - Profi-pumpe Brunnen-Star 550-2-6 Operating Instructions Manual

4" submersible deep well impeller pumps

Advertisement

Available languages

Available languages

2 English
Contents
1. Introduction .......................................................................................................................... 2
2. In general ............................................................................................................................. 2
3. Ranges of application .......................................................................................................... 2

4. Operation ............................................................................................................................. 3

5. Installation scheme .............................................................................................................. 3
6. Security tips .......................................................................................................................... 4
7. Servicing .............................................................................................................................. 4
8. Guarantee regulations ......................................................................................................... 5
9. Recognising and repairing of mistakes ................................................................................ 5
10. Notes on Product Liability .................................................................................................... 5
11. Notes on Disposal ............................................................................................................... 5
12. EU Declaration of Conformity .............................................................................................. 6
13. Technical Data ................................................................................................................... 12
SAfETy INSTRUCTION AND WARNINGS
Please read the user manual
before using the device
Warning sign
1. INTRODUCTION
We would like to congratulate you on the purchase of our pump. We appreciate your trust.
That's why funtional security and operational safety stands by us on first place.
To prevent damage to persons or property, you should read this user manual
carefully. Please observe all safety precautions and instructions for proper use
of the pump. failure to follow the instructions and safety precautions can result
in injury or property damage.
Please keep this manual with the instructions and safety instructions carefully
in order to at any time you can restore them. Please always download the latest
version of the user manual of www.profi-pumpe.de under „downloads". This
shall always prevail.
2. IN GENERAL
The pumps are developed according to the newest stand of technology, manufactured with
much care and go under strict intensive controls. These pumps were optimised by us in particu-
lar for the special demands in dirty water areras. Make sure after unpacking the pump that the
data given on the type label match with the included operating instructions. In case of doubt the
pump is not to be used.
Transport damages are immediately to be reported to the package distributor and to us in writ-
ten form.
3. RANGES Of APPLICATION
These pumps are made for pumping clear water (free of mud and sand and aggressive chemi-
cal substances (see technical data). The water may have to be pre-filtered to 0.2 mm particle
size
The pumps are made for the following ranges of application:
l domestic water use from wells with diameter from 3-inch diameter
l circulation of large accumulations of water from containers
l Other plain water pumping
Pull power plug
Warning of electrical voltage
IMPORTANT!
The pumps are designed for pumping clean water and chemically non-aggressive liquids. Any
guarantee is void in case of improper use. They are not suitable for pumping flammable liquids
or for use in places where there is a risk of explosion. The pumps are designed for home use in
the house and garden.
These pumps are designed for continuous use provided (max. 20 interruptions per hour). Never
run more than 2-3 minutes against a closed valve pump. (Install dry running protection) pump ade-
quately secured against dry running.
The pump must not be used in swimming pools.
Not suitable for use with solar photovoltaic panels.
4. OPERATION
The installation must be performed by a qualified professional.
Please, check each time before using, the electrical connections and the cables are not
damaged. Check before the installation whether the electrical connections are earthed
according to the statutory regulations and are installed. The pump is to be secured
through a RCD circuit breaker with release current of 30 mA.
Also, it is NOT recommended to perform, for example, a cable extension. It is not certain
whether this modification is technically correct, so this warranty is void. It must be en-
sured that the pump is sufficiently cooled during prolonged operation.
5. INSTALLATION SChEME
The installation with pressure switch
must be carried out as shown in the
illustration.
If the installation is carried out wi-
thout a pressure switch, the safety
plug should be installed by a quali-
fied professional.
The pump is supplied without a safe-
ty plug.
The pressure switch shown in the picture
is not included.
A collection of powerful pressure swit-
ches can be found on our website:
http://www.profi-pumpe.de/
English 3
Flexible hose
Panzerschlauch
Towing rope
Zugseil

Advertisement

loading

This manual is also suitable for:

Brunnen-star 110-5.2Brunnen-star 550-2-4Brunnen-star 750-6Brunnen-star 750-6.1Brunnen-star 110-5.1Brunnen-star 550-2-5 ... Show all