General Information General Information Manufacturer R. STAHL Schaltgeräte GmbH R. STAHL (P) LTD., Plot No. - 5 Am Bahnhof 30 Malrosapuram Road, Sengundram Indl. Area 74638 Waldenburg Singaperumal Koil, Kancheepuram Dist., Germany Tamil Nadu – 603 204, INDIA Phone: +49 7942 943-0...
Non-compliance with the instruction can result in light injuries to persons. NOTICE Avoiding material damage Non-compliance with the instruction can result in material damage to the device and / or its environment. Pendant Light Fitting LED 248568 / 647060300120 Series 6470/5 2019-02-13·BA00·III·en·04...
• Use the device in accordance with its intended and approved purpose only. • Always consult R. STAHL Schaltgeräte GmbH if using the device under operating conditions which are not covered by the technical data. • We cannot be held liable for damage to the device caused by incorrect or unauthorised use or non-compliance with these operating instructions.
Function Application range The pendant light fitting 6470/5 is equipment used for lighting areas, work equipment and objects. It can be used indoors and outdoors. The pendant light fitting is approved for use in hazardous areas of Zones 2, 21 and 22.
Enclosure mounting (pivoting) Glass dome Cable gland Wire guard Fastening clip for direct mounting Reflector Enclosure mounting (screwed on) External PE connection Connection terminal of the luminaire Internal PE connection LED driver 248568 / 647060300120 Pendant Light Fitting LED 2019-02-13·BA00·III·en·04 Series 6470/5...
Inrush current = 57 A; Δt = 210 ms peak maximum number of luminaires per miniature circuit breaker at 230 V: Type 10 A 16 A 20 A 25 A Pendant Light Fitting LED 248568 / 647060300120 Series 6470/5 2019-02-13·BA00·III·en·04...
Page 9
30 °C 35 °C 40 °C 45 °C 50 °C 55 °C 60 °C 19912E00 Ambient conditions Operating -40 to +60 °C temperature range Storage temperature -40 to +75 °C 248568 / 647060300120 Pendant Light Fitting LED 2019-02-13·BA00·III·en·04 Series 6470/5...
Page 10
Pendant accessory Ceiling with help of ring bolts as accessory direct on a ceiling Wall cover Wall direct on a wall Pole 25° cover Pole direct on a pole Pendant Light Fitting LED 248568 / 647060300120 Series 6470/5 2019-02-13·BA00·III·en·04...
Wire guard and can easily be mounted later using a mounting screw M6 external reflector For further technical data, see r-stahl.com. Transport and storage • Transport and store the device only in the original packaging. • Store the device in a dry place (no condensation) and vibration-free.
• Do not exceed the maximum ambient temperature due to external heat sources (premature failure of equipment). 7.2.1 Mounting types 19689E00 19690E00 19688E00 Ring eye mounting Ceiling mounting Retaining bracket 19691E00 11419E00 Wall mounting 25° pole mounting Pendant Light Fitting LED 248568 / 647060300120 Series 6470/5 2019-02-13·BA00·III·en·04...
Page 15
11422E00 Retaining bracket mounting • Depending on required slewing angle, attach retaining bracket to mounting part using 4 screws. • Feed the connection cable through the corresponding cable gland. 11423E00 248568 / 647060300120 Pendant Light Fitting LED 2019-02-13·BA00·III·en·04 Series 6470/5...
Page 16
(5) (4 Nm). 16543E00 Pole arm Safety screw adaptor - pole Opening for inspection Pole of restricted breathing 2 x Safety screw Cable gland pole arm - adaptor Adaptor Pendant Light Fitting LED 248568 / 647060300120 Series 6470/5 2019-02-13·BA00·III·en·04...
Page 17
7.2.3 Wire Guard Assembly • Place the wire guard onto the glass dome from below and fasten it using a carrying chain. • Fasten the wire guard with 2 screws. 20507E00 248568 / 647060300120 Pendant Light Fitting LED 2019-02-13·BA00·III·en·04 Series 6470/5...
(2). 19698E00 • Fasten the reflector with 2 screws (3). • Turn the locking plate, push it against the glass and tighten the safety screw (4). 19697E00 Pendant Light Fitting LED 248568 / 647060300120 Series 6470/5 2019-02-13·BA00·III·en·04...
• Carefully hang the body of the light fitting into the mounting part. • Swivel the body of the light fitting towards the mounting part (2). • Tighten (1) Combi-TORX (M8). 19693E00 248568 / 647060300120 Pendant Light Fitting LED 2019-02-13·BA00·III·en·04 Series 6470/5...
Page 20
= protective conductor 20508E00 16373E00 Through wiring of the mains supply connection Through wiring with 2.5 mm cross section for max. 12 A. Earth connection Earth connection internal or external possible. Pendant Light Fitting LED 248568 / 647060300120 Series 6470/5 2019-02-13·BA00·III·en·04...
Page 21
Mounting and installation 7.3.3 Cable entries Luminaires with cable entries and stopping plugs which are not supplied by R. STAHL Schaltgeräte GmbH DANGER Explosion hazard due to impermissible cable entries and stopping plugs! Non-compliance results in severe or fatal injuries.
• Check if the line voltage and the rated operational voltage are consistent. • Check if the permissible conductor diameter for the corresponding cable entries have been used. • Check if the device is closed according to regulations. Pendant Light Fitting LED 248568 / 647060300120 Series 6470/5 2019-02-13·BA00·III·en·04...
• Whether the cable entry is intact and securely tightened • Whether the cables and lines show signs of ageing and damage • Intended use and function. • Restricted breathing of enclosure (see chapter "Restricted breathing test"). 248568 / 647060300120 Pendant Light Fitting LED 2019-02-13·BA00·III·en·04 Series 6470/5...
Page 24
Recommendation Check the luminaire by using the handheld testing instrument for restricted breathing from R. STAHL Schaltgeräte GmbH (see data sheet). The test should only be carried out at constant temperature conditions. If the luminaire is only marked with the type of protection for dust (IIIC), the cable entries and stopping plugs do not need to meet the requirements for restricted breathing (nR).
Page 25
• Use the hand pump to create a vacuum of 0.3 kPa (3 mbar). The test has been passed if after 90 seconds a vacuum of at least 0.15 kPa (1.5 mbar) is still present in the luminaire. 248568 / 647060300120 Pendant Light Fitting LED 2019-02-13·BA00·III·en·04 Series 6470/5...
• Only return or package the devices after consulting R. STAHL! Contact the responsible representative from R. STAHL. R. STAHL's customer service is available to handle returns if repair or service is required. • Contact customer service personally. • Go to the r-stahl.com website.
Malfunction or damage to the device due to the use of non-original components. Non-compliance can result in material damage. • Use only original accessories and spare parts from R. STAHL Schaltgeräte GmbH. For accessories and spare parts, see data sheet on our homepage r-stahl.com.