7. TROUBLE SHOOTING
7.1 L.E.D Display on PM335
No.
LED
COLOUR
1
Mains
Green
2
Str Bat
Green
3
PV
Green
4
Fuse LED
Red
5
Fault
Red
Table 17 Error LED indicator of PM335
7.2 Error Code on Monitor
ERROR
DESCRIPTION
CODE
8001
Lose communication
8003
Battery voltage low
8004
Battery voltage high
8005
PV voltage low
8006
PV voltage high
8010
Battery temperature high
8011
Battery temperature low
8012
Internal temperature high
8013
Starter battery voltage low
Table 18 Error Code List
22
STATUS
Quick flashing
(flash twice every second)
Quick flashing
(flash twice every second)
Quick flashing
(flash twice every second)
Solid
ON
Flash once per cycle
Flash twice per cycle
Flash 3 times per cycle
Flash 4 times per cycle
Flash 5 times per cycle
Flash 6 times per cycle
ERROR
CODE
8014
8015
8016
8017
8018
8027
8028
8030
8031
DESCRIPTION
AC input abnormal
The Starter Battery is 2~13.4V or >16.0V, while
AC power is connected.
Solar input voltage error – Solar Input >50Vdc
Fuse blown, need to check load and replace fuse
Short circuit
Service battery voltage low
Service battery voltage high
PM300-BT unit over temp
Bulk charge timeout
VCR anomaly
Environment over temp
DESCRIPTION
Starter battery voltage high
Over load
Output short circuit
Module protection
Battery maintenance notice
VCR connect is error
VCR disconnect error
Environment temperature is high
Bulk stage time-out