1-1

BI-SM2004 Information

1-1-1

General View

SMOKE DENSITY INDICATOR
Control Panel for Disclose Type
Projector
The Unit has been designed to enable Industry to comply with the Clean Air Act and worldwide ships to comply with Canadian
Shipping Air Pollution CRC, Vol. XV, C. 1404 and Alaska – 18 AAC 50.070, Marine Vessel Visible Emission Standards.
The product consists of Control Panel, Light Beam Projector, Photocell Receiver, Stack Adapter and the Intermediate Adaptor
that clean air is supplied for Glass Cleaning
There are two type of Control Panel, one is disclose type for the application of exposure area, the other type is for inside
installation of Boiler Panel and any other Control Panel.
The Projector and Receiver connected to intermediate Adaptor are mounted on opposite side of the chimney or flue preferably
where a negative pressure exists thus reducing the necessity of frequent cleaning of the optical system.
The presence of smoke in the flue or chimney will cause changed electrical signal between the Projector and Photecell Receiver.
The changed signal is analyzed by Control Panel and give the information on the Digital Display. The Preset Alarm, Low and
High alarm, can be adjusted easily to meet the regulation required per country.