Stone STVI101WT-01 Equipment Manual

Intelligent tft-lcd module

Advertisement

Quick Links

Intelligent TFT-LCD Module
Model
STVI101WT-01
Equipment Manual
STVI101WT-01 Equipment Manual
Release 04/16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STVI101WT-01 and is the answer not in the manual?

Questions and answers

Summary of Contents for Stone STVI101WT-01

  • Page 1 Intelligent TFT-LCD Module Model STVI101WT-01 Equipment Manual STVI101WT-01 Equipment Manual Release 04/16...
  • Page 2: Table Of Contents

    Contents ............................. 3 Preface ........................5 Introduction ....................10 Technical Parameters ....................15 Interface Description ........................17 Accessories ........................19 Installation ....................20 Physical Dimensions ....................21 Command Set Table ....................23 Electrical Components ........................25 Naming Rule ..................26 10 International Certification ..........................
  • Page 3: Preface

    Intelligent Products through its Online services as follows: - Official website: http://en.stone-hmi.com/ - Alibaba platform: http://shuangying-ocean.en.alibaba.com/ http://stonetech.en.alibaba.com/ - Or through telephone 0086-10-84351669 Other support In need of technical queries, please contact STONE representatives in the subsidiaries and branches responsible for your area. STVI101WT-01 Equipment Manual Release 04/16...
  • Page 4: Release

    Preface Trademarks STONE registered trademarks are as below: - STONE - STONE TECH - Intelligent HMI - Intelligent TFT-LCD Module Abbreviations The abbreviation table in this equipment manual is as below: Light Emitting Diode Central Processing Unit Electrostatic Sensitive Device...
  • Page 5: Introduction

    Introduction This chapter contains general information of: - Brief Introduction - Warranty - Product Characteristics - Application Area - Working principle - Operation Processing - Software Operation STVI101WT-01 Equipment Manual Release 04/16...
  • Page 6 & easy VGUS operating system, which can be controlled by Any MCU. The STVI101WT-01 can be used to perform all basic functions, such as text display, image display, curve display as well as touch function, Video & Audio function etc. The User Interface can be more abundant and various.
  • Page 7 The Intelligent TFT-LCD Module communicates with the Customer’s MCU via Commands (HEX Code), and then the MCU would control its connected equipment to work according to the received commands. Figure 1.3-1 Configuration and process control phases STVI101WT-01 Equipment Manual Release 04/16...
  • Page 8 CRC check code header Length (byte) R3:RA Including command, data Check if R2.4 is Description 0x80-0x84 definition and check enabled Example 0xAB,0xBA 0x05 0x81 0x00,0x10 0x20,0x24 More information, please reference the document of Development Guide. Picture 1.4-1 STVI101WT-01 Equipment Manual Release 04/16...
  • Page 9 Introduction 1.7 Software Operation We will offer simple "VUGS Tool Software" to help you to design the new project file for Intelligent TFT-LCD Module on computer. STVI101WT-01 Equipment Manual Release 04/16...
  • Page 10: Technical Parameters

    This chapter contains technical data on: - Physical Parameters: Physical Parameters Display - Hardware Parameters: Processor Memory Interface Power Supply - Storage & Test Electrical Characteristics Ambient Conditions Noise Immunity Radio Interference - Support Device Support Device STVI101WT-01 Equipment Manual -10- Release 04/16...
  • Page 11 Refresh Rate 60Hz 63 ms/frame (16 images/s) Update Speed of per frame Memory Flash Memory Standard 128MB, Extension 1GB According to the capability of the image, Memory Amount for picture Suggest "JPG" format. STVI101WT-01 Equipment Manual -11- Release 04/16 Technical Parameters...
  • Page 12 Threshold 3.3V TTL level Signal 0.1V Output RS232 level V range -15V +15V Voltage Different RS485 level Driver Baud Rate 1200 bps 921600 bps Note: As the brightness lower, the current will also reduce. STVI101WT-01 Equipment Manual -12- Release 04/16...
  • Page 13 RF conduction 150 kHz - 80 MHz 10 V, 80% AM, 1 kHz Burst interference EN 61000-4-4 Supply lines Process data lines Signal lines Radio Interference Radio interference level complying to Class A EN 55011 STVI101WT-01 Equipment Manual -13- Release 04/16...
  • Page 14 (Download one 800×600 picture only take 0.5S) Touch Screen 4 Wire Resistance 6×12/ 8×16/ 12×24/16×32 /24×48 /32×64 Default Font /48×96 /64×128 (Dot Matrix) Picture Support JPG Format Storage Data Support Command Set Unified Simplified Command Sets STVI101WT-01 Equipment Manual -14- Release 04/16...
  • Page 15: Interface Description

    Interface Description This chapter contains the description of the interfaces: - VVC - GND - DIN - DOUT - BUSY - Baud Rate Please notify the interface type before ordering. RS232/ RS485/ TTL level interface. STVI101WT-01 Equipment Manual -15- Release 04/16...
  • Page 16: Release

    Note B: The selection of Baud rate for the serial interface: Baud rate 1200 2400 4800 9600 19200 38600 57600 115200 (bps) Bode_Set 0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 STVI101WT-01 Equipment Manual -16- Release 04/16...
  • Page 17: Accessories

    Accessories This chapter contains the accessories: - Double 8-pin Connect Cable - DB9 Connecting Cable - 8-pin Socket - Mini USB Cable - MCU board for DEMO - Converter - Bezel STVI101WT-01 Equipment Manual -17- Release 04/16...
  • Page 18 USB to RS232 Converter UR4.0 USB to RS485 UR1.0 USB to TTL PS-V043 PS-V050 For: 4.3’’, 5’’, 5.6’’, 7’’, PS-V056 Plastic Bezel 8’’, 10.4’’ TFT-LCD PS-V070 Module. PS-V080 PS-V104 USB Downloading Batch U Storage Disk Function STVI101WT-01 Equipment Manual -18- Release 04/16...
  • Page 19: Installation

    Installation This chapter contains the installation of plastic bezel. STVI101WT-01 Equipment Manual -19- Release 04/16...
  • Page 20: Physical Dimensions

    Physical Dimensions This chapter contains the information of Physical Dimensions. Figure 6-1 STVI101WT-01 dimension STVI101WT-01 Equipment Manual -20- Release 04/16...
  • Page 21: Command Set Table

    Command Table This chapter describes the Commands: Access register interface Access variant register interface Write curve buffer interface Etc. STVI101WT-01 Equipment Manual -21- Release 04/16...
  • Page 22 The TFT LCD module (VGUS serial port screen) includes a 8 K Word, can store the buffer of 8 curves, and can simply and quickly display the curve for users. The data in the curve buffer are 16-bit unsigned numbers. STVI101WT-01 Equipment Manual -22- Release 04/16...
  • Page 23: Electrical Components

    Electrical Components This chapter contains the brands of the components: - TFT Panel - Touch Screen - CPU - LCD Controller - Flash memory - Connecter - Capacitance - IC STVI101WT-01 Equipment Manual -23- Release 04/16...
  • Page 24 Electrical Components Components Supplier TFT Panel LCD Controller Touch Screen Flash Memory Connecter Capacitance STVI101WT-01 Equipment Manual -24- Release 04/16...
  • Page 25: Naming Rule

    VGUS serial product I=Industrial Type ; A=Advanced Type TFT Panel Dimension: 7 inch W=Wide Voltage (4.5V-20V) S=Super Wide Voltage (4.5V-42V) T=With Resistive Touch Screen N=Without Touch Screen C=With Capacitive Touch Screen 0=RS232 4=RS485 1=TTL Hardware Code STVI101WT-01 Equipment Manual -25- Release 04/16...
  • Page 26: International Certification

    International Certification This chapter contains the certification we passed: - CE Certificate - ROHS Certificate - FCC Certificate - ISO9001:2008 Quality System STVI101WT-01 Equipment Manual -26- Release 04/16...
  • Page 27 International Certification CE Certificate FCC Certificate ROHS Certificate ISO9001:2008 STVI101WT-01 Equipment Manual -27- Release 04/16...
  • Page 28: Appendix

    APPENDIX MCU Sample Program MCU Circuit Design ESD Guidelines STVI101WT-01 Equipment Manual -28- Release 04/16...
  • Page 29 APPENDIX A. MCU Sample Program C8051 MCU C Language //----------------------------------------------------------------------------- // Includes //----------------------------------------------------------------------------- #include<reg52.h> //----------------------------------------------------------------------------- // sbit Definitions //----------------------------------------------------------------------------- sbit LED=P0^0; //----------------------------------------------------------------------------- // Global CONSTANTS //----------------------------------------------------------------------------- #define SYSCLK 22118400 // “SYSCLK frequency in Hz” #define BAUD_RATE 115200 // “Baudrate” #define uchar unsigned char #define uint unsigned int uchar pic[3]={0xAA,0x70,0x08};...
  • Page 30 // main() Routine //----------------------------------------------------------------------------- void main (void) // “main function” EA=0; // “Close Interruption” SysInit(); EA=1; // “Open Interruption” delay_ms(40); while (1) pic_str(); // “Picture switching” Return 0; //----------------------------------------------------------------------------- // End Of File //----------------------------------------------------------------------------- STVI101WT-01 Equipment Manual -30- Release 04/16...
  • Page 31 APPENDIX B. MCU Circuit Design STVI101WT-01 Equipment Manual -31- Release 04/16...
  • Page 32 Most plastics are capable of carrying high charges and it is therefore imperative that they be kept away from sensitive components. When handling electrostatic sensitive devices, make sure that persons, workplaces and packages are properly grounded. STVI101WT-01 Equipment Manual -32- Release 04/16...
  • Page 33 (never use plastic bags or foils). With assemblies containing fitted batteries, make sure that the conductive packing does not come into contact with or short-circuit battery connectors. If necessary, cover the connectors beforehand with insulating tape or insulating material. STVI101WT-01 Equipment Manual -33- Release 04/16...
  • Page 34: Glossary

    Hex Code, the MCU can control the TFT Module via the command set. Configuration file It can be created by the softwares. Download Download the image, configuration files and data through mini USB port or SD card. Download mode Through mini USB port or SD card. STVI101WT-01 Equipment Manual -34- Release 04/16...
  • Page 35 Enables the user to enter values which are subsequently send to the MCU. Micro Control Unit, it is widely used in the industrial control. Normal operation Operating unit operating mode in which messages are displayed and screens can be operated. STVI101WT-01 Equipment Manual -35- Release 04/16...
  • Page 36 A screen displays all the logically related process data on the operating unit, whereby the individual values can be modified. Touch panel This is an operating unit without keyboard. The touch panel (abbreviated to TP) is operated via the contact-sensitive screen elements. STVI101WT-01 Equipment Manual -36- Release 04/16...

Table of Contents