Advertisement

Connector M12-A
Connector M12-C
1
ArmorPoint 24V dc Input Modules, Series A
Cat. Nos. 1738-IB2M12, -IB4M8, -IB4M12, -IB8M8, -IB8M12,
-IB8M23, -IV4M12, -IV8M8, -IV8M12, -IV8M23
The ArmorPoint™ I/O family consists of modular I/O modules. The
sealed IP67 housing of these modules requires no enclosure. (Note
that environmental requirements other than IP67 may require an
additional appropriate housing.) I/O connectors are sealed M8 (pico),
M12 (micro) or M23 styles. The mounting base ships with the module.
Connector M8-A
Connector M8-B
Connector M8-C
Connector M8-D
1738-IB8M12
1738-IB8M8
Connector M8-E
Connector M8-F
Connector M8-G
Connector M8-H
43683
Connector M12-B
LED Indicators
Connector M12-D
43680
Installation Instructions
LED
Indicators
1738-IB8M23
Publication 1738-IN002B-EN-E - November 2004
M23
Connector
LED
Indicators
43682

Advertisement

Table of Contents
loading

Summary of Contents for AB Quality ArmorPoint A Series

  • Page 1 Installation Instructions ArmorPoint 24V dc Input Modules, Series A Cat. Nos. 1738-IB2M12, -IB4M8, -IB4M12, -IB8M8, -IB8M12, -IB8M23, -IV4M12, -IV8M8, -IV8M12, -IV8M23 The ArmorPoint™ I/O family consists of modular I/O modules. The sealed IP67 housing of these modules requires no enclosure. (Note that environmental requirements other than IP67 may require an additional appropriate housing.) I/O connectors are sealed M8 (pico), M12 (micro) or M23 styles.
  • Page 2: Important User Information

    ArmorPoint 24V dc Input Modules, Series A Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.ab.com/manuals/gi) describes some important differences between solid state equipment and hard-wired electromechanical devices.
  • Page 3 ArmorPoint 24V dc Input Modules, Series A Environment and Enclosure ATTENTION This equipment is intended for use in overvoltage Category II applications (as defined in IEC publication 60664-1), at altitudes up to 2000 meters without derating. This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR Publication 11.
  • Page 4 ArmorPoint 24V dc Input Modules, Series A Mount the I/O Base To mount the base on a wall or panel, use the screw holes provided in the base. The module must be mounted on a grounded metal IMPORTANT mounting plate or other conductive surface. A drilling dimensions mounting illustration for the base with an adapter is shown below.
  • Page 5 ArmorPoint 24V dc Input Modules, Series A Install the Digital To install the digital input module: Input Module 1. Using a bladed screwdriver, rotate the keyswitch on the mounting base clockwise until the number 1 aligns with the notch in the base. 2.
  • Page 6: Wire The Modules

    ArmorPoint 24V dc Input Modules, Series A Wire the Modules Following are wiring instructions for the modules. 1738-IB2M12, 1738-IB4M12, and 1738-IV4M12 (view into connector) Pin 1 - 24V dc Pin 2 - No Connect Pin 3 - Common Pin 4 - Input 0 (M12-A) Input 1 (M12-B) Input 2 (M12-C) (1738-IB4M12 and 1738-IV4M12 modules only) Input 3 (M12-D) (1738-IB4M12 and 1738-IV4M12 modules only)
  • Page 7: Communicate With Your Module

    ArmorPoint 24V dc Input Modules, Series A 1738-IB8M23 and 1738-IV8M23 (view into connector) Pin 1 - Input 0 Pin 7 - Input 6 Pin 2 - Input 1 Pin 8 - Input 7 10 10 12 12 Pin 3 - Input 2 Pin 9 - Return (Com) Pin 4 - Input 3 Pin 10 - Return (Com)
  • Page 8: Troubleshoot With The Indicators

    ArmorPoint 24V dc Input Modules, Series A 1738-IB8M8, -IB8M12, -IB8M23, -IV8M8, -IV8M12, and -IV8M23 Modules Message size: 1 Byte Produces (Rx) Ch7 Ch6 Ch5 Ch4 Ch3 Ch2 Ch1 Ch0 Channel status Where: 0 = off, 1 = on Troubleshoot With 1738-IB8M12 the Indicators Module Status Indicators...
  • Page 9: Specifications

    ArmorPoint 24V dc Input Modules, Series A Indication Probable Cause Network Status Device is not on line: - Device has not completed dup_MAC_ID test. - Device not powered - check module status indicator. Flashing Green Device is on line but has no connections in the established state. Green Device is on line and has connections in the established state.
  • Page 10 ArmorPoint 24V dc Input Modules, Series A ArmorPoint Digital Input Modules Input Delay Time, ON to OFF 0.5 ms hardware + (0-63 ms selectable Input Point Density 2, 4, or 8 Field Power Bus Supply Voltage Range, 10-28.8V dc Nominal 24V dc Keyswitch Position General Specifications...
  • Page 11 ArmorPoint 24V dc Input Modules, Series A General Specifications (continued) Emissions CSPR 11: Group 1, Class A Enclosure Type Rating Meets IP65/66/67 (when marked) Mounting Base Screw Torque #8 screw, 7.5 in. lbs. in Aluminum, 16 in. lbs. in Steel Weight Imperial (Metric) 0.64 lb.
  • Page 12: Rockwell Automation Support

    Rockwell Automation Support Rockwell Automation provides technical information on the web to assist you in using its products. At http://support.rockwellautomation.com, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools.

Table of Contents