Symptoms
Possible
q
causes
Checking
method
checking
criteria
Remedies
-.. -
Stator sub.coil
I
I
Rotor
Rotor
Slip ring
Slip ring
1
I
Short circuit of the coil
Short circuit of the coil
Short circuit of the coil
Short circuit of the coil
----
----
I
I. Contamination
of the
I. Contamination
of the
brush's contact surface
brush's contact surface
2. Abnormal
abrasion of the
2. Abnormal
abrasion of the
brush's contact surface
brush's contact surface
Measure resistance between
the terminals with a circuit
tester
(Measure with a 6P coupler)
I
In case the measured resis-
tance is lower than 15% of
the standard, it suggests a
short circuit.
/
Measure resistance between
the terminals with a circuit
tester
(Measure with a 6P coupler)
In case the measured resis-
tance is lower than 15% of
the standard, it suggests a
short circuit.
Measure resistance value
between the slip rings with
a circuit tester
1. In case the resistance is
lower than 553, it suggests
short circuit
2. In case the measured
resistance is more than
1452, check the slip
rings.
Confirm condition
of the
brush's contact surface
1. If the brush's contact
surface is contaminated,
clean it.
2. In case of abnormal abra.
sion, replace it.