SUGGESTIONS FOR INSTALLATION

Do not install in the following conditions:
X
Ensure the sensor's line of
sight is free from any false
alarm
bushes, trees, etc.
tention to these as they may
change seasonally).
Height of installation and protection distance:
Note that here the model references do not match the Pro-
tection Distance of Spread of Beam.
Protection Distance
30 m
ABT-30
ABT-60
60 m
80 m
ABT-80
100 m
ABT-100
Direction of Installation:
Horizontally 180° (±90°)
Because angle of reflection mirror is adjustable ±90°
horizontally and ±12° vertically, the unit can be installed in
various directions.
sources
such
as
(Pay at-
Spread of Beam
0.9 m
1.8 m
2.4 m
3.0 m
Vertically 20° (±10°)
X
Ensure the sensors
are mounted on a
stable and firm foot-
ing.
Protection Distance
In case of jump phenomena as shown in the above
sketch of long distance links, units are available with
modified pulse frequencies on request.
X
Ensure strong sunlight or
car headlights do not shine
directly on to the receiver.
(Within ±2° from the optical
axis is not recommended).