  • Page 2: Parts Description

    PARTS DESCRIPTION 2. Obscuration Time Wiring Connection Adjustment Hole Terminal (Only for receiver) Main Body Indication Cover Lamp 1. Monitor Jack (Only for receiver) Tamper Vertical Angle Adjusting Screw Viewfinder Lens Horizontal Angle Screw Locking Adjusting Bracket 1. Indication Lamp Receiver: •...
  • Page 3: Suggestions For Installation

    Note that here the model references do not match the Pro- tection Distance of Spread of Beam. Protection Distance Spread of Beam 30 m 0.9 m ABT-30 ABT-60 60 m 1.8 m 80 m 2.4 m ABT-80 Protection Distance 100 m 3.0 m...
  • Page 4: Installation

    4, and confirm system operation before replacing covers. Wiring Distance Transmitter Model ABT-30 ABT-60 ABT-80 ABT-100 Voltage 12 V 24 V 12 V 24 V 12 V 24 V 12 V 24 V Alarm Diameter of Wire...
  • Page 5 ADJUSTMENT OF OPTICAL AXIS (Aiming Beam) Remove transmitter In each unit, remove the At the transmitter, look through the receiver covers and apply viewfinder from it’s normal viewfinder, with your eyes about 10 cm. power to the units. storage location and place From it.
  • Page 6: Confirm Operation

    ADJUSTMENT OF SHADING TIME Set the obscuration time of the receiver by Scale 2 Scale 3 Scale 4-5 Scale 1 adjusting the obscuration time control to the required setting according to the sketch to the right. The obscuration time should be set lower to detect faster moving targets, however care should be taken to note the environmental con- Fast Running...
  • Page 7: Troubleshooting Guide

    TROUBLESHOOTING GUIDE Symptom Possible Cause Remedy Transmitter LED does not light. Improper voltage supplied. Check power supply and wiring. Receiver power LED does not light. Improper voltage supplied. Check power supply and wiring. Alarm LED does not light, even when Infrared beam from transmitter is reflect- Remove reflecting object or change in- beams are blocked.
  • Page 8: Specifications

    SPECIFICATIONS Model ABT-30 ABT-60 ABT-80 ABT-100 Indoor 30 m 60 m 80 m 100 m Protection Distance Outdoor 90 m 180 m 240 m 300 m Max. Arrival Distance 360 m 650 m 800 m 1100 m Infrared Beam 2 Beams...
  • Page 9: Outer Dimensions

    OUTER DIMENSIONS Flange & Pole Mounting Bracket 2 - Ø4.5 72.5 Pole Ø38 - 50 mm...