Maintenance

5
Maintenance
Caution – risk of injury!
If installation, removal or maintenance work is not carried out correctly, there is a risk of injuries at the connection
points, if pressurised water suddenly escapes.
Ensure proper installation, removal or maintenance work.
Ensure that the system is de-pressurised before performing installation, removal or maintenance work at the
connection points.
Caution – Risk of injury due to falls or bumps!
Bruising from falls or bumps at system components during installation.
Wear personal protective equipment (helmet, protective clothing, gloves, safety boots).
Caution – risk of burning!
Excessively hot surfaces in heating systems can cause burns on the skin.
Wear protective gloves.
Please place appropriate warning signs in the vicinity of the device.
For maintenance, proceed as follows:
Check the cartridge capacity at least every six months. To check the capacity use the actual water level or the water level entry in the
machine log before installation.
Replace the cartridge when 90 % of the capacity is spent.
Replace the cartridge at the latest after 18 months.
Dispose of the spent cartridge with normal household waste.