Wireless single channel signal transmission system for safety edges

Advertisement

3
Transmitter
3.1
DIP switch setting according to sensor (safety edge, switch contact)
Example: RFGate 3.2.T
Sensor connection DIP switch
ON
1
2
8k2
4
Receiver
4.1
Wiring: Power supply and outputs with control
Power supply
1
2
+/~ –/~
12–36V
AC/DC
4.2
Status Outputs (relay contacts)
No power supply
System ready, sensor not pressed
Sensor pressed
4.3
DIP switches
*
ON
Transmission frequency
869.525 MHz
1
ON
868.15 MHz
1
* = factory setting
4.4
Cable routing, strain relief
 Determine the cable routing
 Break out the corresponding part of the cover if necessary
 Punch hole into the grommet
Break out ...
2
Sensor connection DIP switch
ON
1
2
8k2
3
4
5
6
Control unit with
8.2 kOhm input
Terminals
Terminals
4–5
3–6
closed
open
8k2
closed
closed
open
... or use holes
in the base plate
Note:
IN1 = active
IN2 = not used
Further instructions see separate transmitter manuals.
Conductor cross section 0.25 – 0.75 mm
i
3
4
5
6
Control unit with
NC input
Wicket door open (with RFGate 3.W.T)
Broken cable between sensor and transmitter closed
Transmitter with empty batteries
 Thread cable
 Fix cable with the clamp (➔ strain relief)
Cable Ø: 3.1 – 5.2 mm
i
Hint:
2
3
4
5
6
Control unit with
1.2 kOhm NC input
Terminals
Terminals
4–5
3–6
closed
open
open
closed
open