Advertisement

Quick Links

Omniksol GPRS Kit User Manual
Omnik New Energy Co., Ltd.

Advertisement

Table of Contents
loading

Summary of Contents for Omnik Omniksol GPRS Kit

  • Page 1 Omniksol GPRS Kit User Manual Omnik New Energy Co., Ltd.
  • Page 2 User manual version V2.3 Overview of GPRS Kit Functions Omniksol GPRS Kit is developed by Omnik as an external communication monitoring device, including a SIM card inside, which transfers collected data to the web server through mobile network for users to monitor their systems remotely. The device can distinguish between single-phase and three-phase inverters automatically and indicate current status from LEDs on its front panel.
  • Page 3: Table Of Contents

    User manual version V2.3 catalog Part 1. 485 Card Install SOP ....................4 1. Disassembly ........................4 2. Install ..........................5 Part 2. Omniksol –GPRS KIT User Manual ................7 1. Unpack ..........................7 2. Installation of SIM card ..................... 7 3.Installation of the data collector ..................
  • Page 4: Part 1. 485 Card Install Sop

    User manual version V2.3 Part 1. 485 Card Install SOP 1. Disassembly Picture 1-1 Unscrew the four screws on the interface panel with the screwdriver as shown in Picture1-1 and keep the screws aside. Picture 1-2...
  • Page 5: Install

    User manual version V2.3 Picture1-3 Unscrew the two-holed water-proofing connector from the interface panel. as shown in Picture1-2 1-3. 2. Install Pick out the net cable and the water-proofing connector from the package and follow the Picture2-1 A , put the net cable in from the gap, as shown in Picture2-1 B, then put the net cable one after another into the kneck of the interface panel.
  • Page 6 User manual version V2.3 Insert the 485 card lightly from the position showed in Picture2-2:A Picture 2-2 Finish the installation ,see Picture2-3 Picture2-3...
  • Page 7: Part 2. Omniksol -Gprs Kit User Manual

    User manual version V2.3 Part 2. Omniksol –GPRS KIT User Manual 1. Unpack After unpacking the box, please check the parts according to the below list. Contact the manufacturer immediately, should you find any damage, missing or wrong model of the device or any parts.
  • Page 8: Picture

    User manual version V2.3 2. Make 2 holes φ6mm with a drill at the mark place, the hole depth should be not less than 30mm 3. Knock the plastic expansion pipe with a rubber hammer into the hole of the wall; 4.
  • Page 9: Connecting Data Collector And Pv Inverter

    User manual version V2.3 4. Connecting data collector and PV inverter 4.1 Data collector interface and connecting wire interface Line sequence of T568B 1. orange with white 2. orange 3. green with white RJ45 crystal head 4. blue 5. blue white white 6.
  • Page 10 User manual version V2.3 4.2 Connecting procedure Both ends of the connecting wire are RJ45 network cable connector,all the line sequence are T568B. 4.2.1 Single inverter connection 1. cut off the power of the inverter; 2. Plug one end of the network cable into any RJ45 port of the inverter; 3.
  • Page 11: Debugging

    User manual version V2.3 : Note Before connection, you must cut off the power of the inverter. Please make sure all the connections are finished before switching on the power in the inverter and data collector. Otherwise it would cause person injury or equipment damage.
  • Page 12 User manual version V2.3 GSM module is normal, signal strength is good. blinking GSM module is normal, signal strength is so so. GSM module is normal, signal strength is bad; or GSM STATUS module is abnormal. Note: GSM module abnormal means GSM module has not been registered on the Internet.
  • Page 13 User manual version V2.3 The antenna Check if the antenna connection is not good; connection is not If so please tighten it. good. Change the installation place of the GSM signal is equipment or the place of the antenna, weak search for a place with good signal quality No SIM card or SIM card is in bad...
  • Page 14: Register The Login Website

    6. Register the login website You can use the web browser that the PV monitoring website supports: IE8,Firefox, Chrome,safari. Input the Omnik Portal login website:http://www.omnikportal.com/,open the login interface as below picture 6-1, click“register”and enter the register interface, fill in and submit the document according to the demand. After the user’s information upload onto the server and the register finishes successful, please enter your email to activate your account.
  • Page 15 Owner Click and enter the configure interface Picture 6-2 Remarks: please read the <Omnik service agreement >carefully, the enclosure is the cost list for all the countries, please choose your operators Owner means the final user 6.2.1 “Owner” Account Click and choose the aim pic Click”OK”save the pic...
  • Page 16: Login The Pv Monitoring System To Manage The Power Station

    User manual version V2.3 Click the map, choose the installation site Select, and choose it to be the share mode, other user can see Finish the register Picture 6-3 Picture 6-4 7. Login the PV monitoring system to manage the power station After the successful register and account activation,open the login interface as below picture 7-1, input the correct email and code and enter the PV monitoring system, then you can monitor and manage the power station.
  • Page 17 User manual version V2.3 Input the correct email and code Picture 7-1 7.1 “Owner” User Interface Power station list Picture 7-2...
  • Page 18 User manual version V2.3 Choose your aim station and enter Edit or delete the case Picture 7-3 List of power stations Not yet open Back to 7-2 interface Enter the sharing case Enter the configure “company account”interface , Add one case under your account same as 7-3 Reset password Picture 7-4 navigation bar...
  • Page 19 User manual version V2.3 Change case Case info search Real-time power and generated energy switchover Print current figure Power station info Energy saving Picture 7-5 Main interface of power station...
  • Page 20 User manual version V2.3 Internal temperature Latest data collecting time Picture 7-6 Real Time Interface Choose the aim inverter Parameter options Picture 7-7 History Interface...
  • Page 21 User manual version V2.3 , Click ,turn to picture 7-7 Picture 7-8 Alert Interfaces The interface same as picture 7-3 Picture 7-9 System Setting Interface...
  • Page 22: Iphone & Ipad Application

    Picture 7-10 System Setting Interface 8. IPhone & iPad application After registration of the power station, you can input the key words: Omnik, solar, inverter, PV, energy ,plant, monitor at the app store, then you can download the Omnik solar (iPhone) and Omnik Solar HD(iPad) at app store.
  • Page 23 User manual version V2.3 Picture 8-1 1. Log in interface 2. Power station list interface 3. Main interface 4. Daytime curve interface...
  • Page 24: Contacts

     Device model  Data collector serial number  The number of connected inverter Omnik New Energy Co., Ltd. Add: Xinghu Road No.218 bioBAY Park C2, Suzhou China Zip code 215213 Fax: +86 512 6295 6682 Tel: +86 512 6295 6676 Mail: Sales@omnik-solar.com...

Table of Contents