LG 60UL3E Installation Manual
Hide thumbs Also See for 60UL3E:

Advertisement

INSTALLATION MANUAL
LG Digital Signage
(MONITOR SIGNAGE)
Please read this manual carefully before operating your set and
retain it for future reference.
60UL3E
70UL3E
Copyright © 2018 LG Electronics Inc. All Rights Reserved.
www.lg.com

Advertisement

Table of Contents
loading

Summary of Contents for LG 60UL3E

  • Page 1 INSTALLATION MANUAL LG Digital Signage (MONITOR SIGNAGE) Please read this manual carefully before operating your set and retain it for future reference. 60UL3E 70UL3E www.lg.com Copyright © 2018 LG Electronics Inc. All Rights Reserved.
  • Page 2: Table Of Contents

    Table of contents KEY CODES Location and Function of Controls Parts and Button EXTERNAL CONTROL DEVICE SETUP Basic functions RS-232C Setup First Use Wizard USB to Serial converter with USB Cable RS-232C with RS-232C Cable Language & Location Set ID Communication Parameters Installation Menu Command reference list...
  • Page 3: Location And Function Of Controls

    Location and Function of Controls Parts and Button Basic functions Power On (Press) Power Off (Press and Hold) Menu Control (Press Menu Selection (Press and Hold All running apps will close. You can access and adjust the menu by pressing the button when Signage is on. You can use the function when you access menu control.
  • Page 4: First Use Wizard

    First Use Wizard * Image shown may differ from your Signage. Language & Location (Depending upon model) • Select the Language and Country. Some countries need to select the Time Zone.
  • Page 5: Installation Menu

    Installation Menu * Image shown may differ from your Signage. Introduction The abundant functions for Signage linked with software installation can be projected on OSD as ‘Installation Menu’ . The wide range of features can be performed simply on additional window to enhance the Signage’s easy installation and convenient operation for System Integrators.
  • Page 6: Public Display Settings

    Public Display Settings When ‘Public Display Settings’ is set to On (Work), all functions of Public Display Mode apply. Public Display Settings • Decide to work all functions of ‘Public Display Settings’ or not by setting ‘Public Display Settings’ as On (Work) or Off (Do Not Work).
  • Page 7: Volume

    ‘Local Key Operation’ will be worked by below. IR Operation • Decide whether work the LG remote control or not. - When ‘IR Operation’ is set to 'Normal' , all remote keys are available. - 'Use PWR Only' makes block all remote keys except power key.
  • Page 8: Limited Mode

    Limited Mode • Configure Signage function’s limitation. When selected to ‘On’ , following sub-menus will be worked by below. Menu Display • Function to decide whether work with menu (including relevant menus too) of control key (On – Enter possible) or not (Off – Enter Impossible). - Although select Off (Enter impossible), the action that press a Menu button for 5 seconds to enter ‘Installation Menu’...
  • Page 9: Power On Default

    Power On Default • Set to On (Work) or Off (Do Not Work). • When ‘Power On Default’ is set to Off, it is not applied to the subordinate Input, A/V Setting, Aspect Ratio menu. • When Power On Default is set to On, it can set by entering the subordinate menu. Input •...
  • Page 10: Network

    Network MAC Address • Displays the MAC address (not customizable). Network Setting One-click network connection • Connects easily to a wired network. • This menu supports to connect to an available network. To connect to a network through Set Expert •...
  • Page 11: Wake On Lan

    Wake On LAN • Sets the Wake On LAN function to Enable or Disable. - The Wake On LAN feature enables the Signage to receive software updates and/or be powered ON upon receipt of Wake Up Frame packets and/or Magic Packet data via the wired LAN. To facilitate use of this feature, note that the appropriate wired connection must be made.
  • Page 12: General

    General Configuration Setup On Timer Operation • It is a mode to select ‘Timer Power On’ working one time or repeatedly. • 'Once': ‘Timer Power On’ in the user menu operates only one time when the Timer Power On menu is set to On. •...
  • Page 13 (Depending upon model) • You can configure the DPM (Display Power Management) function. • If this option is not set to Off, the Signage set enters the DPM mode when there is no input signal. • If you set this option to Off, the DPM function is disabled. Sustain Aspect Ratio (Depending upon model) •...
  • Page 14: Set Id Setup

    Set ID Setup Set ID Lock • Set the ‘Set ID’ item in GENERAL Menu whether to activate or not. • Set to On (Work) or Off (Do Not Work). Set ID • Set the ‘Set ID’ of Signage Set with 1~99. Power Saving Static Saving •...
  • Page 15: Hcec Setup

    (Depending upon model) • You will have 2 modes to choose [Default], [HCEC]. • If [Default] is selected, you can use SIMPLINK which is provided in LG Signage. Also you can enable and disable SIMPLINK through SIMPLINK MENU. IR Decoding •...
  • Page 16: Clock Setup

    Clock Setup Clock Source • You can select ‘Off’ , ‘NTP’ , ‘Admin’ . • NTP : Clock is synchronized using Network Time Protocol. It's only enabled when network cable is connected. • Admin : It's automatically set to Admin when clock is updated by commercial protocols like TVLink-HCEC. •...
  • Page 17: Signage Manager

    Signage Manager You can update files from USB to Signage through the Signage manager.
  • Page 18 Ez Download • Ez Download is a function that enables users to download the desired items all at once, such as EPK (software update file), TLL, Image, Micom. - Images and Software Update files should be copied into the folder named LG_DTV on the USB. »...
  • Page 19 Export Clone File • “Export Clone File” creates “TLL” file in USB root folder. “TLL” file can be used to “Import Clone File”. While writing is in process, the user must not turn Signage off nor unplug the USB memory card. The following reference images might be slightly different.
  • Page 20 Import Clone File • Once the internal Signage data is written to the USB memory card, the user can start “Import Clone File” process with the data file generated and stored in USB memory card. The user should not turn Signage off nor unplug the USB memory card while processing.
  • Page 21 Image Download * Image shown may differ from your Signage. • If there are more than two USB Memory Device, It is possible to select the USB. • The download sequence is Image Download Select Image(s) Download. • Image files should be in “LG_DTV” folder. - Boot Logo Image »...
  • Page 22 Software Update ► Update Signage Software • This feature updates Signage software through the EPK file in USB. • “.EPK” files should be in “LG_DTV” folder. • The download sequence is Software Update Update Signage Software Select file(EPK) UPDATE.
  • Page 23 ► Update Micom Software • This feature updates Micom software through the txt file in USB. • “.txt” files should be in “LG_DTV” folder. • The download sequence is Software Update Update Micom Software Select file(txt) UPDATE.
  • Page 24: Usb Download Menu

    USB Download Menu USB Cloning • An Installer can quickly set up and clone multiple Signage sets at a property. These cloned Signages will all have the same Master Signage Setup: Public Display Mode Installation Menu settings, User A/V settings. This newer procedure significantly decreases the installation time that would be necessary if the standard RS-232C method were used instead.
  • Page 25: Key Codes

    KEY CODES • This feature is not available for all models. Code Code Function Note Function Note (Hex) (Hex) Remote control Remote control Button Button (POWER) Remote control (Power On/Off) Button Remote control Remote control Button Button Remote control Remote control Button Button ENERGY...
  • Page 26: External Control Device Setup

    USB Type (TV) (Signage) (PC) • LG signage supports PL2303 chip-based (Vendor ID : 0 x 0557, Product ID : 0 x 2008) USB to serial converter RS-232C IN (CONTROL & SERVICE) which is not made nor provided by LG.
  • Page 27: Set Id

    Connector type : D-Sub 9-pin male RS-232C (Serial port) RS-232C configurations 7-Wire Configurations 3-Wire Configurations (Standard RS-232C cable) (Not standard) Signage Signage D-Sub 9 D-Sub 9 D-Sub 9 D-Sub 9 Set ID For Set ID number, see “Real data mapping (Hexadecimal : Decimal)”. Press to access the main menus.
  • Page 28: Communication Parameters

    Communication Parameters • Baud rate : 9600 bps (UART) • Stop bit : 1 bit • Data length : 8 bits • Communication code : ASCII code • Parity : None • Use a crossed (reverse) cable. Command reference list (Depending upon model) COMMAND1 COMMAND2...
  • Page 29: Transmission / Receiving Protocol

    TRANSMISSION / RECEIVING PROTOCOL * (Depending upon Model) Transmission [Command1][Command2][ ][Set ID][ ][Data][Cr] [Command 1] : First command to control the signage. (j, k, m or x) [Command 2] : Second command to control the signage. [Set ID] : You can adjust the set ID to choose desired signage ID number in option menu. Adjustment range is 1 to 99.
  • Page 30 1 Power (Command: k a) 3 Screen Mute (Command: k d) ► To control power on or off of the set. ► To select screen mute on/off. Transmission Transmission [k][d][ ][Set ID][ ][Data][Cr] [k][a][ ][Set ID][ ][Data][Cr] Data 00 : Screen mute off (Picture on) / Video mute off Data 00 : [Off] Data 01 : Screen mute on (Picture off) Data 01 : [On]...
  • Page 31 7 [Brightness] (Command: k h) 11 OSD Select (Command: k l) ► To adjust screen brightness. You can also adjust ► To select OSD (On Screen Display) on/off when brightness in the picture settings. controlling remotely. Transmission Transmission [k][h][ ][Set ID][ ][Data][Cr] [k][l][ ][Set ID][ ][Data][Cr] Data Min : 00 to Max : 64 Data 00 : [Off]...
  • Page 32 15 [Equalizer] (Command : j v) 17 Auto Configuration (Command: j u) (Only RGB support model) ► Adjust EQ of the set. ► To adjust picture position and minimize image Transmission shaking automatically. It works only in RGB (PC) [j][v][ ][Set ID][ ][Data][Cr] mode.

This manual is also suitable for:

70ul3e

Table of Contents